Comparing the Sensitivity and Specificity of Two-Dimensional Shear Wave Elastography and Fine Needle Aspiration in
Maryam Farghadani1, Sayyid Amir Tabatabaei1, Roozbeh Barikbin1
1Department of Radiology, Isfahan university of Medical Sciences, Isfahan, Iran.
Background:
Malignancy in thyroid nodules is a common clinical problem, and epidemiological studies have shown that it is increasing. Since malignancy is a very important problem in treating patients and misdiagnosis leads to many physical and financial damages, the importance of diagnostic methods becomes more important. Hence, the aim of this study was to investigate the sensitivity and specificity of the two dimensional-shear wave elastography (2D-SWE) diagnostic method in comparison with fine-needle aspiration (FNA) in determining the malignant thyroid nodules.
Materials And Methods:
This study is cross-sectional which was performed on 57 thyroid nodules are proven by conventional ultrasound. Afterward, 2D-SWE images were taken with the help of a superSonic ultrasound machine. Then, FNA was performed from the thyroid nodules and the specimens were evaluated in a single specialized thyroid pathology center. The results of conventional sonography and 2D-SWE were compared with histopathologic results as a gold standard method. The elasticity quantity was recorded by measuring the amount of the appropriate quantities by a recording machine and analyzed using the SPSS and MedCalc software.
Results:
From 57 nodules studied, 50 nodules were evaluated with benign diagnosis and 7 nodules with the malignant diagnosis. Among all the parameters recorded by the machine, SWE. ratio provided the highest surface area under the curve and the highest sensitivity and specificity with 0.94, 100% and 84%, respectively, and a cut-off point of 1.7.
Conclusion:
The 2D-SWE method and the conventional ultrasound can be good references for decision making about with the thyroid nodules.
Related Concept Videos
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
The Wave Nature of Light
Fineness of Cement
Direct...
Fineness Modulus
Consider performing sieve analysis on sand through a set of ASTM sieves. The weight of aggregate retained in each sieve and pan placed at the bottom is recorded, as given in Column B of Table 1.
To determine the fineness modulus of...
Shearing Stress
The average shearing stress can be calculated by dividing the shear by the area of the cross-section.
Shearing Strain