Related Experiment Video
Updated: Jan 24, 2026

Detection of Human Leukocyte Antigen Biomarkers in Breast Cancer Utilizing Label-free Biosensor Technology
Published on: March 24, 2015
Detection and Quantification of Label-Free Infectious Adenovirus Using a Switch-On Cell-Based Fluorescent Biosensor
Miguel Ricardo Guerreiro1,2, Daniela Filipa Freitas1,2, Paula Marques Alves1,2
1iBET, Instituto de Biologia Experimental e Tecnológica , Apartado 12, 2781-901 Oeiras , Portugal.
Abstract:
Reliable and fast viral detection and quantification protocols are a requirement for the advance of basic research and clinical approaches with wild type or recombinant viruses. However, available cell-based assays are either time-consuming or require labeled viral particles, which may alter virus biology or pose safety issues in clinical applications. Since adenoviruses constitute a major healthcare burden but also, when engineered, widely used vectors in vaccination and gene and oncolytic therapies, herein we developed a genetically encoded switch-on fluorescent biosensor consisting of a cyclized Green fluorescent protein-cVisensor-with an adenoviral protease cleavable site as a switch. After initial sensor optimization (35% increase in performance), whole-cell biosensors were established-by stably expressing cVisensor in mammalian cells-and used for live-cell monitoring of adenovirus infection as the intracellular biosensor is specifically activated by the viral protease. A rapid flow cytometry-based bioassay using cVisensor cells was established 48 h postinfection, showing an estimated limit of detection of 105 infectious particles/mL, in-line with previously reported flow cytometry assays requiring labeled virus, and significantly faster than standard plaque-forming assays requiring up to 14 days. cVisensor was also successfully applied in the detection of HIV-1 protease activity, validating its wider potential for the detection of other viruses. Overall, this work presents a fast and easy method for detection and quantification of label-free infectious virus, allowing the establishment of new biosensing platforms for basic research in virology and biotechnological applications of recombinant virus biopharmaceuticals.
Related Concept Videos
Switching of BJT
Cut-off Mode ("Off" State): In this state, both the emitter-base and collector-base junctions are...
Labeling Emotion
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Agonism and Antagonism: Quantification
To quantify these effects, researchers use a dose-response curve, which provides valuable information about the potency and efficacy of a drug. Potency refers to...
Base Excision Repair
The first step of...
Detection of Gross Error: The Q Test

