Related Experiment Video
Updated: Jan 24, 2026

Ovarian Cancer Detection Using Photoacoustic Flow Cytometry
Published on: January 17, 2020
Critical Analysis of Particle Detection Artifacts in Synaptosome Flow Cytometry
Benjamin D Hobson1,2,3, Peter A Sims1,2,4
1Department of Systems Biology, Columbia University Irving Medical Center, New York, NY 10032 bh2573@columbia.edu pas2182@columbia.edu.
None:
Flow cytometry and fluorescence-activated sorting are powerful techniques that hold great promise for studying heterogeneous populations of submicron particles such as synaptosomes, but many technical challenges arise in these experiments. To date, most flow cytometry studies of synaptosomes have relied on particle detection using forward scatter (FSC) measurements and size estimation with polystyrene (PS) bead standards. However, these practices have serious limitations, and special care must be taken to overcome the poor sensitivity of conventional flow cytometers in the analysis of submicron particles. Technical artifacts can confound these experiments, especially the detection of multiple particles as a single event. Here, we compared analysis of P2 crude synaptosomal preparations from murine forebrain on multiple flow cytometers using both FSC-triggered and fluorescence-triggered detection. We implemented multicolor fluorescent dye-based assays to quantify coincident particle detection and aggregation, and we assessed the false colocalization of antigens in immunostaining analyses. Our results demonstrate that fluorescence triggering and proper dilution can control for coincident particle detection, but not particle aggregation. We confirmed previous studies showing that FSC-based size estimation with PS beads underestimates biological particle size, and we identified pervasive aggregation in the FSC range analyzed in most synaptosome flow cytometry studies. We found that analyzing P2 samples in sucrose/EDTA/tris (SET) buffer reduces aggregation compared to PBS, but does not completely eliminate the presence of aggregates, especially in immunostaining experiments. Our study highlights challenges and pitfalls in synaptosome flow cytometry and provides a methodological framework for future studies.
Related Concept Videos
Flow Cytometry
In...
Critical Region, Critical Values and Significance Level
In hypothesis testing, a sample statistic is converted to a test statistic using z, t, or chi-square distribution. A critical region is an area under the curve in probability distributions demarcated by the critical value. When the test statistic falls in this region, it suggests that the null hypothesis must be rejected. As this region contains all those values of the...
Critical Values
Critical Thinking
Colleges and universities are...
Critical Thinking I
Critical Thinking II

