Related Experiment Video
Updated: Jan 24, 2026

Simultaneous Video-EEG-ECG Monitoring to Identify Neurocardiac Dysfunction in Mouse Models of Epilepsy
Published on: January 29, 2018
Robust Comparison of Simultaneous EEG Recordings Using Kalman Filters and Gaussian Mixture Models
Niels von Stein1, Jonas Schulte-Coerne1, Stephan M Jonas2
1Department of Medical Informatics, RWTH Aachen University, Germany.
Abstract:
In this manuscript we propose a novel method to compare simultaneously recorded electroencephalography (EEG) signals from different devices. Although standard methods like correlation and spectral analysis give quantitative answers to this question, these methods often penalize certain artifacts such as eye blinking too strongly. In our analysis we instead utilize an unsupervised labeling technique to evaluate the matching of two signals by comparing their label sequences. The proposed method was successfully tested on artificial data, where it showed a reduced deviation from the ground truth compared to the correlation coefficient. Furthermore, the method was applied on a real use-case to assess the quality of a low-cost EEG device compared to a clinical one. Here it showed more consistent results than the correlation coefficient, while it also did not rely on outlier removal prior to the analysis. However, the proposed method still suffers from accidental matches of labels, so that unrelated data sets may be assigned an unexpectedly high matching score. This paper suggests extensions to the proposed method, which could improve this issue.
Related Concept Videos
Mixtures of Acids
A Mixture of a Strong Acid and a Weak Acid
In a mixture of a strong acid and a weak acid, the strong acid dissociates completely and becomes a source of almost all the hydronium ions...
Mixtures of Acids
In a strong and weak acid mixture, the strong acid dissociates completely and becomes a source of almost all the hydronium ions present in the solution. In contrast, the weak acid shows...
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
Active Filters
Racemic Mixtures and the Resolution of Enantiomers

