Related Experiment Video
Updated: Jan 24, 2026

A Novel Rescue Technique for Difficult Intubation and Difficult Ventilation
Published on: January 17, 2011
Comparative evaluation of Airtraq™ and GlideScope® videolaryngoscopes for difficult pediatric intubation in a Pierre
Neel Desai1, Mae Johnson2,3, Kat Priddis2
1Department of Anaesthetics, Guy's and St Thomas' NHS Foundation Trust, Westminster Bridge Road, London, UK. neel_d83@hotmail.com.
Abstract:
Airway management in children is associated with anatomical and physiological challenges compared with adults. Pierre Robin sequence (PRS) is a condition characterized by micrognathia, glossoptosis, and cleft palate and related to a difficult airway. Both the Airtraq™ and GlideScope® have never been previously directly compared in PRS. Our aim was to evaluate the performance of these two airway devices in a PRS manikin for ethical and practical reasons. Between April and July 2017, 26, pediatric intensive care clinical fellows or trainees from a tertiary pediatric center were recruited to participate. In this prospective and randomized crossover trial, all participants first set up the Airtraq™ and the GlideScope® and then used these videolaryngoscopes to intubate an AirSim® PRS manikin. Our primary outcome measure was the duration of the successful intubation attempt. Duration of the successful intubation attempt was 18.1 (14.2-34.9 [10.2-51.3]) s for the Airtraq™ compared to 31.1 (18.7-55.6 [6.2-119]) s for the GlideScope® (p = 0.045). Setup time was 50.0 ± 6.9 s for the Airtraq™ and 27.8 ± 8.6 s for the GlideScope® (p < 0.001).Conclusion: Even though setup time was longer, the characteristics of intubation performance were superior with the Airtraq™ relative to the GlideScope® in an AirSim® PRS manikin. What is Known: • Several case reports have described the successful use of Airtraq™ to intubate children with Pierre Robin sequence. • The GlideScope® has demonstrated similar rates of first-attempt successful intubation to flexible fiberoptic bronchoscopy in a Pierre Robin sequence manikin. What is New: • In the hands of pediatric non-airway specialists, the characteristics of intubation performance, including the duration of the successful intubation attempt, are superior with the Airtraq™ compared with the GlideScope® in a Pierre Robin sequence manikin. • Setup time for the Airtraq™ is, however, longer relative to that for the GlideScope®.
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...
Pharmacokinetics in Pediatric Patients: Drug Excretion
Pharmacokinetics in Pediatric Patients: Drug Distribution