Related Experiment Video
Updated: Jan 24, 2026

Using an Automated Hirschberg Test App to Evaluate Ocular Alignment
Published on: March 24, 2020
Evaluation of Visual Quality in Pseudophakic Eyes with Different Ocular Spherical Aberrations
Xuan Liao1,2, Jia Lin1,2, Qingqing Tan1,2
1Department of Ophthalmology, Affiliated Hospital of North Sichuan Medical College , Nanchong , Sichuan Province , China.
Abstract:
Purpose: To evaluate the effects of different residual total ocular spherical aberration (SA) on objective and subjective visual quality in pseudophakic eyes. Methods: This prospective consecutive study comprised 171 patients with age-related cataract and undergone unilateral uneventful phacoemulsification. All participants were divided into four groups based on residual ocular SA at 6 mm pupil: negative SA (≤-0.10 μm, group A), neutral SA (0.00 ± 0.05 μm, group B), slightly positive SA (0.10 ± 0.05 μm, group C), and more positive SA (0.20 μm, group D), respectively. Subjective visual acuity and contrast sensitivity, and objective optical quality and ocular aberrations were analyzed 3 months postoperatively. Results: There was no significant difference in baseline measurements across all groups. Postoperatively, no statistically significant differences were found in visual acuity between groups (P > .05), while differences reached statistical significance in mesopic contrast sensitivity at 12 and 18 cpd (P < .01). There were significant differences in ocular SA and higher-order aberrations at 6 mm pupil, as well as in optical quality parameters (P < .05). Group C showed a minimum value of objective scatter index (1.17 ± 0.55) but maximum values of modulation transfer function cutoff (31.94 ± 9.18) and optical quality value OV 100% (1.07 ± 0.31), indicating lower intraocular scattering and superior optical quality. Conclusions: This comprehensive evaluation is conducive to deepening the understanding of visual and optical performance of pseudophakic eye. A modest amount of positive ocular SA seemed to be a more preferable option for enhancing visual quality after aspheric ntraocular lense (IOL) implantation.
Related Concept Videos
Spherical Coordinates
Spherical and Cylindrical Capacitor
Conventionally, considering the symmetry, the electric field between the concentric shells of a spherical capacitor is directed radially outward. The magnitude of the field,...
Gravity between Spherical Bodies
This assumption can be proved easily by showing that the expression for gravitational potential energy between a hollow sphere of mass (M) and a point mass (m) is the same as it would be for a pair of extended...
Gravitation Between Spherically Symmetric Masses
Gauss's Law: Spherical Symmetry
Quality of Water

