Aims:
Acute kidney injury (AKI) is a common complication following transcatheter aortic valve implantation (TAVI) and is associated with increased risk for short- and long-term mortality. In patients undergoing percutaneous coronary intervention (PCI), forced diuresis with matched hydration has been shown to reduce the incidence of AKI by ∼50%. The aim of the present study was to evaluate whether forced diuresis with matched intravenous hydration reduces AKI in patients undergoing TAVI.
Methods And Results:
Reducing Acute Kidney Injury (REDUCE-AKI) was a single-centre, prospective, randomized, double-blind sham-controlled clinical trial, designed to examine the effect of an automated matched saline infusion with urine output for the prevention of AKI in patients undergoing TAVI. A total of 136 TAVI patients were randomized, 68 in each group. Mean age was 83.9 ± 5 years and 41.2% were males. There were no differences in baseline characteristics between the two groups. The rate of AKI was not statistically different between the groups (25% in the active group vs. 19.1% in the sham group, P = 0.408). There was a significant increase in long-term mortality in the active group (27.9% vs. 13. 2% HR 3.744, 95% CI 1.51-9.28; P = 0.004). The study was terminated prematurely by the Data Safety Monitoring Board for futility and a possible signal of harm.
Conclusions:
Unlike in PCI, forced diuresis with matched hydration does not prevent AKI in patients undergoing TAVI, and might be associated with increased long-term mortality. Future studies should focus on understanding the mechanisms behind these findings.
Clinicaltrials.Gov Registration:
NCT01866800, 30 April 2013.
More Related Videos
06:04Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
Published on: August 8, 2025
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Acute Kidney Injury IV: Diagnostic Studies and Prevention
Acute Kidney Injury I: Introduction
Acute Kidney Injury II: Pathophysiology
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Acute Kidney Injury VI: Nursing Management
Acute Kidney Injury V: Interprofessional Care