Related Experiment Video
Updated: Jan 24, 2026

Bacterial Detection & Identification Using Electrochemical Sensors
Published on: April 23, 2013
A novel electrochemical sensor based on carbon nanotubes array for selective detection of dopamine or uric acid
Yang Yang1, Meixian Li1, Zhiwei Zhu1
1Beijing National Laboratory for Molecular Sciences, College of Chemistry and Molecular Engineering, Peking University, Beijing, 100871, PR China.
Abstract:
A novel single-walled carbon nanotubes array-modified glassy carbon electrode (SWCNTs array-GCE) has been fabricated through a simple electrochemical technique. Benefitting from their vertically aligned configuration on the electrode surface, the modified single-walled carbon nanotubes can be used more efficiently in comparison with other modified method. The as-fabricated SWCNTs array-GCE can separate the anodic oxidation potential of dopamine (DA), uric acid (UA) and ascorbic acid (AA) with well-defined peak separation in the presence of each other, and thus employs as a new electrochemical sensor for selective determination of DA and UA. It can make a further improvement of the electrocatalytic ability of the electrode to perform an acetone pretreatment to SWCNTs array-GCE before electrochemical detection, which has been confirmed by atomic force microscope and electrochemical impedance spectroscopic measurements. Especially, unlike other carbon nanotubes-based electrode at which only two redox pairs are observed for dopamine oxidations, a third two-electron oxidation of 5,6-dihydroxyindole to indole-5,6-quinone can be clearly observed at acetone-pretreated SWCNTs array-GCE, showing the excellent electrocatalytic performance of as-fabricated electrode toward dopamine. The practicability of SWCNTs array-GCE was evaluated for the selective detection of DA and UA in real sample solutions of human serum and urine. It revealed acceptable recovery results in the range of 94-104%, indicating that it might be a promising platform for further biosensor development.
More Related Videos
Related Concept Videos
Lewis Acids and Bases
A coordinate covalent bond (or dative bond) occurs when one of the atoms in the bond provides both bonding electrons. For example, a coordinate covalent bond occurs when a water molecule combines with a hydrogen ion to form a hydronium ion. A coordinate covalent bond also results when...
Bicarbonate-Carbonic Acid Buffer
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Ions as Acids and Bases
Salts are ionic compounds composed of cations and anions, either of which may be capable of undergoing an acid or base ionization reaction with water. Aqueous salt solutions, therefore, may be acidic, basic, or neutral, depending on the relative acid-base strengths of the salt’s constituent ions. For example, dissolving the ammonium chloride in water results in its dissociation, as described by the equation:
Acids, Bases and Neutralization Reactions
Bronsted-Lowry Acids and Bases

