Related Experiment Video
Updated: Jan 24, 2026

The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022
High Variability of Acetabular Offset in Primary Hip Osteoarthritis Influences Acetabular Reaming-A Computed
Christian Merle1, Moritz M Innmann1, Wenzel Waldstein2
1Department of Orthopaedic and Trauma Surgery, University Hospital Heidelberg, Heidelberg, Germany.
Background:
The objectives of the present study were to (1) evaluate the accuracy and reliability of native acetabular offset (AO) measurements performed on conventional supine anterior-posterior (ap) pelvis radiographs with reference to computed tomography (CT) in patients with end-stage hip osteoarthritis (OA); (2) determine the minimum and maximum amount of medialization of the center of rotation (COR) simulating different reaming techniques; and (3) identify patients at increased risk of excessive medialization of the COR.
Methods:
A consecutive series of corresponding 131 CT scans and radiographs of patients with primary hip OA was evaluated using validated software for three-dimensional acetabular and femoral measurements. We simulated the implantation of a hemispherical press-fit cup comparing anatomic and conventional reaming techniques and assessed corresponding changes in AO.
Results:
Standardized ap pelvis radiographs allowed for an accurate and reliable assessment of AO compared with CT. Cup placement in the most lateral position (anatomic reaming technique) resulted in a mean implant-related medialization of 5.9 ± 3.4 mm. Anatomic cup placement did not require reaming to the true floor in 64 hips (49%). With the conventional reaming technique, the total medialization of the COR (implant-related and reaming-related) was 6.8 ± 2.9, with 34% of cases having a medialization ≥8 mm.
Conclusion:
The present study highlights the variability of acetabular anatomy in patients with primary OA. AO can be accurately and reliably determined on conventional radiographs and appears to be independent of femoral shape and geometry. Depending on the preferred reaming technique a substantial number of patients appear at risk for excessive cup medialization.
More Related Videos
08:40Author Spotlight: A Novel 3D-Printed Titanium Implant for Minimally Invasive Treatment of Hip Dysplasia in Young Dogs
Published on: April 19, 2024
06:02Anatomical Reconstructions of the Human Cardiac Venous System using Contrast-computed Tomography of Perfusion-fixed Specimens
Published on: April 18, 2013
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Factors Influencing Drug Absorption: Anatomical Parameters
Anatomical Positions
The body is upright, facing forward, and standing erect.
The feet are parallel and flat on the floor.
The arms are hanging by the...
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...
Random Variables
Uppercase letters such as X or Y denote a random variable. Lowercase letters like x or y denote the value of a random variable. If X is a random variable, then X is written in words, and x is given as a number.
For example, let X = the...