Related Experiment Video
Updated: Jan 24, 2026

Immunoglobulin G N-Glycan Analysis by Ultra-Performance Liquid Chromatography
Published on: January 18, 2020
Determination of cocaine adulterants in human urine by dispersive liquid-liquid microextraction and high-performance
Pedro Rafael da Silva1, Laís Cristina Santana Sena2, Rubens Pedro Lorena Silva1
1Pharmaceutical Science Department, Federal University of Pernambuco, Prof. Artur de Sá S/N; Cidade Universitária, Recife, PE, 50740-521, Brazil.
Abstract:
This study aimed to determine simultaneously five major street cocaine adulterants (caffeine, lidocaine, phenacetin, diltiazem, and hydroxyzine) in human urine by dispersive liquid-liquid microextraction (DLLME) and high-performance liquid chromatography. The chromatographic separation was obtained in gradient elution mode using methanol:water plus trifluoroacetic acid 0.15% (v/v) (pH = 1.9) at 1 mL min-1 as mobile phase, at 25 °C, detection at 235 nm, and analysis time of 20 min. The effect of major DLLME operating parameters on extraction efficiency was explored using the multifactorial experimental design approach. The optimum extraction condition was set as 4 mL human urine sample alkalized with 0.5 M sodium phosphate buffer (pH 12), NaCl (15%, m/v), 300 μL acetonitrile (dispersive solvent), and 800 μL chloroform (extraction solvent). Linear response (r2 ≥ 0.99) was obtained in the range of 180-1500 ng mL-1 with suitable selectivity, quantification limit (180 ng mL-1), mean recoveries (33.43-76.63%), and showing relative standard deviation and error (within and between-day assays) ≤15%. The analytes were stable after a freeze-thaw cycle and a short-term room temperature stability test. This method was successfully applied in real samples of cocaine users, suggesting that our study may contribute to the appropriate treatment of cocaine dependence or with the cases of cocaine acute intoxication.
More Related Videos
10:52Radiolabeling and Quantification of Cellular Levels of Phosphoinositides by High Performance Liquid Chromatography-coupled Flow Scintillation
Published on: January 6, 2016
05:26A Standardized Liquid Biopsy Preanalytical Protocol for Downstream Circulating-Free DNA Applications
Published on: September 16, 2022
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Types of Detectors
Molecular Comparison of Gases, Liquids, and Solids
Rise of Liquid in a Capillary Tube