Related Experiment Video
Updated: Jan 24, 2026

Diffusion Tensor Magnetic Resonance Imaging in the Analysis of Neurodegenerative Diseases
Published on: July 28, 2013
Nonrigid registration of medical image based on adaptive local structure tensor and normalized mutual information
Tiejun Yang1, Qi Tang1, Lei Li1
1College of Informational Science and Engineering, Henan University of Technology, High-Tech Zone, Zhengzhou City, China.
Abstract:
Nonrigid registration of medical images is especially critical in clinical treatment. Mutual information is a popular similarity measure for medical image registration; however, only the intensity statistical characteristics of the global consistency of image are considered in MI, and the spatial information is ignored. In this paper, a novel intensity-based similarity measure combining normalized mutual information with spatial information for nonrigid medical image registration is proposed. The different parameters of Gaussian filtering are defined according to the regional variance, the adaptive Gaussian filtering is introduced into the local structure tensor. Then, the obtained adaptive local structure tensor is used to extract the spatial information and define the weighting function. Finally, normalized mutual information is distributed to each pixel, and the discrete normalized mutual information is multiplied with a weighting term to obtain a new measure. The novel measure fully considers the spatial information of the image neighborhood, gives the location of the strong spatial information a larger weight, and the registration of the strong gradient regions has a priority over the small gradient regions. The simulated brain image with single-modality and multimodality are used for registration validation experiments. The results show that the new similarity measure improves the registration accuracy and robustness compared with the classical registration algorithm, reduces the risk of falling into local extremes during the registration process.
Related Concept Videos
Mutual Inductance
When two circuits carrying time-varying currents are close to one another, the magnetic flux through each circuit varies because of the changing current in the other circuit. Consequently, an emf is induced in each circuit by the changing current in the other. Therefore, this type of emf is called...
Inertia Tensor
The diagonal components of the inertia tensor matrix represent the moments of inertia concerning the principal axes of the object. These primary axes are defined as the axes where the object experiences the least...
Local Anesthetics: Chemistry and Structure-Activity Relationship
Normal Stress
When a rod is under axial loading, the internal forces and corresponding stress are normal to the plane of the section, so it is termed normal stress. It's important to...
Normal Distribution
Variation: Normal Distribution, Range, and Standard Deviation