Related Experiment Video
Updated: Jan 24, 2026

Contrast Enhanced Vessel Imaging using MicroCT
Published on: January 27, 2011
Deep convolutional neural network for reduction of contrast-enhanced region on CT images
Iori Sumida1, Taiki Magome2, Hideki Kitamori3,4
1Department of Radiation Oncology, Osaka University Graduate School of Medicine, 2-2 Yamada-oka, Suita, Osaka, Japan.
Abstract:
This study aims to produce non-contrast computed tomography (CT) images using a deep convolutional neural network (CNN) for imaging. Twenty-nine patients were selected. CT images were acquired without and with a contrast enhancement medium. The transverse images were divided into 64 × 64 pixels. This resulted in 14 723 patches in total for both non-contrast and contrast-enhanced CT image pairs. The proposed CNN model comprises five two-dimensional (2D) convolution layers with one shortcut path. For comparison, the U-net model, which comprises five 2D convolution layers interleaved with pooling and unpooling layers, was used. Training was performed in 24 patients and, for testing of trained models, another 5 patients were used. For quantitative evaluation, 50 regions of interest (ROIs) were selected on the reference contrast-enhanced image of the test data, and the mean pixel value of the ROIs was calculated. The mean pixel values of the ROIs at the same location on the reference non-contrast image and the predicted non-contrast image were calculated and those values were compared. Regarding the quantitative analysis, the difference in mean pixel value between the reference contrast-enhanced image and the predicted non-contrast image was significant (P < 0.0001) for both models. Significant differences in pixels (P < 0.0001) were found using the U-net model; in contrast, there was no significant difference using the proposed CNN model when comparing the reference non-contrast images and the predicted non-contrast images. Using the proposed CNN model, the contrast-enhanced region was satisfactorily reduced.
Related Concept Videos
Convolution Properties II
The width property indicates that if the durations of input signals are T1 and T2, then the width of the output response equals the sum of both durations, irrespective of the shapes of the two functions. For instance, convolving two rectangular pulses with durations of 2 seconds and 1 second results in a function with a width of 3 seconds.
The area property asserts that the area under the...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Convolution Properties I
The commutative property reveals that the input and the impulse response of an LTI (Linear Time-Invariant) system can be interchanged without affecting the output:
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Oxidation-Reduction Reactions

