Related Experiment Video
Updated: Jan 24, 2026

Fabrication of Small Caliber Stent-grafts Using Electrospinning and Balloon Expandable Bare Metal Stents
Published on: October 26, 2016
Morphologic performance analysis of the Relay nonbare stent graft in dissected thoracic aorta
Mario Lescan1, Martin Czerny2, Mikolaj Berezowski2
1Department of Thoracic and Cardiovascular Surgery, University Medical Center Tübingen, Tübingen, Germany.
Objective:
The aim of this study was to evaluate morphologic changes in dissected aortas after thoracic endovascular aortic repair (TEVAR) with the use of the Relay Nonbare stent graft stent graft by focusing on the geometric stent graft's performance in remodeling aortas.
Methods:
We conducted a retrospective three-dimensional computed tomography analysis preoperatively, postoperatively, and 6 months after TEVAR in patients with residual dissection after type A and those with acute and chronic type B dissections at two German centers.
Results:
Thirty-nine acute and 54 chronic aortic dissections were included. Median follow-up was 200 (interquartile range, 109-617) days. TEVAR induced aortic remodeling in both groups. Complete false lumen thrombosis along the stent graft (postoperative, 73%; follow-up, 84%; P < .0001) led to a decrease in aortic diameter at the middle stent graft level (preoperative, 45.9 mm [38.6-56.6] vs follow-up, 43.6 [37.4-52.4] mm; P = .009). True lumen expansion was observed in both groups and peaked in acute dissections in the distal landing zone (acute, +9.3 mm vs chronic, +5.8 mm; P < .0001). Migration was 2 (0-5) mm, and bird-beak and endoleak type IA rates were 20% and 4%, respectively. There was no retrograde type A dissection. Distal stent graft-induced new entry occurred in 15%; the major risk factor for incidence was the stent graft's wedge apposition angle (odds ratio, 1.365 [confidence interval, 1.115-1.671]; P = .003).
Conclusions:
TEVAR with the use of the Relay NBS promotes aortic remodeling in acute and chronic dissections, entailing a low risk of migration, type IA endoleaks, and retrograde type A dissections. Wedge apposition was the predominant risk factor for distal stent graft-induced new entry.
Related Concept Videos
Thoracic Aorta
Directional Relays
Overcurrent Relays
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
Differential Relays
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
Pilot and Numeric Relaying