Related Experiment Video
Updated: Jan 24, 2026

Author Spotlight: An Automated Method for Assessing Visual Acuity in Infants and Toddlers Using an Eye-Tracking System
Published on: March 17, 2023
Simulation of visual acuity by personalizable neuro-physiological model of the human eye
Csilla Fülep1, Illés Kovács2,3, Kinga Kránitz2
1Department of Atomic Physics, Budapest University of Technology and Economics, H-1111, Budapest, Hungary. fulepcsilla@gmail.com.
Abstract:
We present a model of the whole visual train to estimate an individual's visual acuity based on their eye's physical properties. Our simulation takes into account the optics of the eye, neural transmission and noise, as well as the recognition process. Personalized input data are represented by the ocular wavefront aberration and pupil diameter, both either coming from in vivo measurements of a subject or being produced by optical design software using a schematic eye. This flexibility opens the door to a broad range of potential applications, such as objective visual acuity measurements and intraocular lens design. Our algorithm contains only two adjustable neural parameters: additive noise σ, and discrimination range δρ, with their values being experimentally calibrated by fitting the results of simulations to the outcome of real acuity tests performed on healthy young subjects with normal vision (visual acuity: 0…-0.3 logMAR range). It was established that by using fixed values of σ = 0.10 and δρ = 0.0025 for each person examined, the residual of the acuity simulations averaged over the calibration group reached its minimum at 0.045 logMAR.
Related Concept Videos
Clearance Models: Physiological Models
The organ's clearance rate depends on the blood flow to the organ and the extraction ratio (E). The extraction ratio describes the organ's...
Model Approaches for Pharmacokinetic Data: Physiological Models
Physiological Pharmacokinetic Models: Assumption with Protein Binding
Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models
Physiological Barriers
The blood endothelial barrier is the most porous of these. It allows all small ionized, un-ionized, and lipophilic molecules to pass through the endothelial lining into the interstitial space...
Liver Physiology
Metabolic Regulation:
The liver is the central organ involved in regulating blood composition. It stabilizes blood glucose levels, maintaining them within the range of 70–110 mg/dL. When these levels drop, the liver breaks down glycogen reserves and releases glucose into the bloodstream. It can...

