Toward the characterisation of non-intentionally added substances migrating from polyester-polyurethane lacquers by
Elsa Omer1, Emmanuelle Bichon2, Sébastien Hutinet2
1LABERCA, Oniris, INRA, F-44307, Nantes, France; ARDAGH MP WEST France SAS, F-72200, Crosmières, France; CEISAM, Université de Nantes, UMR CNRS 6230, F-44322, Nantes, France.
Abstract:
Polyester-polyurethane lacquer, used to cover the inner surface of metallic food contact materials, may transfer non-intentionally added substances (NIAS) to the food. The identification of such a diversity of compounds, considered as migrating substances, requires taking advantage of complementary analytical platforms. Therefore, four types of gas chromatography-mass spectrometry (GCMS) couplings were investigated and compared for their abilities to identify migrating substances after acetonitrile extraction of two commercialised lacquers. In parallel, various ionisation sources, i.e. electron ionisation (EI) (70 eV and soft energies) and atmospheric-pressure chemical ionisation (APCI) as well as various mass analysers, i.e. quadrupole, time-of-flight (low and high resolution) and Orbitrap, were tested. Comparison of mass spectra with a commercial library for EI ionisation source led to the identification of two NIAS compounds, isophorone diisocyanate and 4,4'-diphenylmethane diisocyanate. Additionally, many cyclic oligoesters (four monomer units) were unambiguously identified according to supplier's declaration on starting materials used, primarily based on the molecular ion observed by APCI mode and characteristic fragment ions. High resolution mass analysers also enhanced confidence level in such NIAS identification. One- and two-dimensional GC were also investigated for separation assessment. Although GC × GC did not reveal additional NIAS, its use provided a valuable mapping of oligomers according to monomers composition. These results were compared to our previously published LC-MS study, carried out on the same lacquer samples. This study shows that LC and GC, along with their related ionisation techniques and their own selectivity, are complementary approaches, revealing different classes of compounds covering a wide range of volatility and polarity.
More Related Videos
07:25Quantitative Metabolomics of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: January 5, 2021
08:14Extraction of Non-Protein Amino Acids from Cyanobacteria for Liquid Chromatography-Tandem Mass Spectrometry Analysis
Published on: December 9, 2022
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Applications of the Ideal Gas Law: Molar Mass, Density, and Volume