Related Experiment Video
Updated: Jan 24, 2026

Three-dimensional Optical-resolution Photoacoustic Microscopy
Published on: May 3, 2011
Comparison of noise reduction methods in photoacoustic microscopy
Gokhan Guney1, Nasire Uluc2, Aytac Demirkiran2
1Department of Biomedical Engineering, Ankara University, 06830, Ankara, Turkey.
Abstract:
Photoacoustic microscopy (PAM) is classified as a hybrid imaging technique based on the photoacoustic effect and has been frequently studied in recent years. Photoacoustic (PA) signals are inherently recorded in a noisy environment and are also exposed to noise by system components. Therefore, it is essential to reduce the noise in PA signals to reconstruct images with less error. In this study, an image reconstruction algorithm for PAM system was implemented and different filtering approaches for denoising were compared. Studies were carried out in three steps: simulation, experimental phantom and blood cell studies. FIR low-pass and band-pass filters and Discrete Wavelet Transform (DWT) based filters (mother wavelets: "bior3.5″, "bior3.7″, "sym7″) with four different thresholding techniques were examined. For the evaluation purposes, Root Mean Square Error (RMSE), Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) metrics were calculated. In the simulation studies, the most effective methods were obtained as: sym7/heursure/hard thresh. combination (low and medium level noise) and bior3.7/sqtwolog/soft thresh. combination (high-level noise). In experimental phantom studies, noise was classified into five levels. Different filtering approaches perform better depending on the SNR of PA images. For the blood cell study, based on the standard deviation in the background, sym7/sqtwolog/soft thresh. combination provided the best improvement and this result supported the experimental phantom results.
Related Concept Videos
Oxidation-Reduction Reactions
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Evolutionary Relationships through Genome Comparisons
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...

