Related Experiment Video
Updated: Jan 24, 2026

Deep Neural Networks for Image-Based Dietary Assessment
Published on: March 13, 2021
Slice interpolation of medical images using enhanced fuzzy radial basis function neural networks
1Department of Radiation Convergence Engineering, College of Health Science, Yonsei University, 1Yonseidae-gil, Wonju, Gangwon, 220-710, South Korea.
Abstract:
Volume data composed of complete slice images play an indispensable role in medical diagnoses. However, system or human factors often lead to the loss of slice images. In recent years, various interpolation algorithms have been proposed to solve these problems. Although these algorithms are effective, the interpolated images have some shortcomings, such as less accurate recovery and missing details. In this study, we propose a new method based on an enhanced fuzzy radial basis function neural network to improve the performance of the interpolation method. The neural network includes an input layer (six input neurons), three hidden layers of neurons, and the output layer (one output neuron), and we propose a patch matching method to select the input variables of the neural network. Accordingly, we use two normal pending images to be interpolated as the input. Final output data is obtained by applying the trained neural network. In examining four groups of medical images, the proposed method outperforms five other methods, achieving the highest similarity image metric (ESSIM) values of 0.96, 0.95, 0.94, and 0.92 and the lowest mean squared difference (MSD) values of 35.5, 41.2, 50.9, and 47.1. In addition, for a whole MRI brain volume data experiment, the average MSD and ESSIM values of the proposed method and other methods are (41.62, 0.95) and (57.13, 0.90), respectively. The results indicate that the proposed method is superior to the other methods.
Related Concept Videos
Reconstruction of Signal using Interpolation
Network Function of a Circuit
Protein Networks
These interactions can be represented through maps depicting protein-protein interaction networks, represented as nodes and edges. Nodes are circles that are representative of a protein,...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Network Covalent Solids
To break or to melt a covalent network solid, covalent bonds must be broken. Because covalent bonds are relatively strong, covalent network solids are typically...

