Related Experiment Video
Updated: Jan 24, 2026

Neuro-rehabilitation Approach for Sudden Sensorineural Hearing Loss
Published on: January 25, 2016
Subclinical conductive hearing loss significantly reduces otoacoustic emission amplitude: Implications for test
Christoph Kreitmayer1, Steven C Marcrum1, Erin M Picou2
1Department of Otolaryngology, University Hospital Regensburg, Regensburg, Germany.
Objectives:
Distortion product otoacoustic emissions (DPOAEs) are a time-efficient, non-invasive means of assessing the integrity of active inner ear mechanics. Unfortunately, the presence of even relatively minor conductive hearing loss (CHL) has been suggested to reduce the clinical utility of DPOAEs significantly. The primary aims of this study were to systematically evaluate the impact of CHL on DPOAE amplitude and to determine if ear-specific primary tone level manipulations can be used to mitigate CHL impact and recover DPOAE measurability.
Methods:
For 30 young adults (57 ears) with normal hearing, DPOAEs were obtained for f2 = 1-6 kHz. Observed DPOAE amplitudes were used to generate ear- and frequency-specific models with the primary tone levels, L1 and L2, as inputs and predicted DPOAE amplitude, LDP, as output. These models were then used to simulate the effect of CHL (0-15 dB), as well as L1 manipulations (0-15 dB), on DPOAE measurability.
Results:
Mean LDP for every CHL condition was significantly different from that for all other conditions (p = <.001), with a mean LDP attenuation of 8.7 dB for every 5 dB increase in CHL. Mean DPOAE measurability in response to a standard clinical stimulation paradigm of L1/L2 = 65/55 (dB SPL) was determined to be 99%, 84%, 37%, and 9% in the presence of 0, 5, 10, and 15 dB CHL, respectively. In the presence of 10 dB CHL, altering L1 resulted in an approximately 25% increase in DPOAE responses.
Conclusion:
Subclinical CHL loss is sufficient to significantly impair DPOAE measurability in a meaningful proportion of otherwise healthy ears. However, through strategic alteration of primary tone levels, the clinician can mitigate CHL impact and at least partially recover DPOAE measurability.
More Related Videos
06:27Simple Surgical Induction of Conductive Hearing Loss with Verification Using Otoscope Visualization and Behavioral Clap Startle Response in Rat
Published on: October 26, 2019
03:49Author Spotlight: Optimizing EAS with Long Electrodes for Enhanced Cochlear Coverage and Hearing Preservation
Published on: October 11, 2024
Related Concept Videos
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Adaptations that Reduce Water Loss
Hearing
Emission Spectra
Line Loss
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...