Characterization of adrenal lesions on chemical shift MRI: comparison of 1.5 T and 3 T MRI
İlhan Hekimsoy1, Ezgi Güler2, Mustafa Harman2
1Department of Radiology, Ege University School of Medicine, 35100, Izmir, Turkey. ihekimsoy@hotmail.com.
Purpose:
To compare three chemical shift MRI techniques [two-dimensional (2D) dual gradient echo (dGRE), 3D VIBE, and 3D VIBE-Dixon] at 3 T and 2D dGRE technique at 1.5 T to assess their ability of detecting microscopic fat in adrenal adenomas and differentiating between adenomas and non-adenomas.
Methods:
Seventy-eight patients with 97 lesions (78 adenomas, 19 non-adenomas) underwent both 1.5 T and 3 T chemical shift MRI. The Wilcoxon signed-ranked test was used to determine if there was significant difference between the signal intensity index (SII) values of each technique to assess their ability to detect microscopic fat in adrenal adenomas. ROC analysis was performed for the SII values of each technique, the adrenal-to-spleen SI ratio of 2D dGRE technique at 3 T, and the fat fraction values of the 3D VIBE-Dixon technique to identify the optimal threshold for differentiation of adrenal adenomas from non-adenomas.
Results:
For detection of microscopic fat, the mean SII value of 2D dGRE technique at 1.5 T was significantly higher than that of the chemical shift imaging techniques at 3 T (p = 0.001). For discrimination of adenomas from non-adenomas, the area under the curve (AUC) and 95% confidence interval values of 2D dGRE technique at 1.5 T and 2D dGRE, 3D VIBE, 3D VIBE-Dixon techniques at 3 T were calculated as 1.00 (1.00-1.00), 0.991 (0.978-1.00), 0.999 (0.995-1.00), 0.993 (0.979-1.00), respectively, for the SII.
Conclusion:
Chemical shift MRI at 1.5 T using the 2D dGRE technique provided the most accurate differentiation between adenomas and non-adenomas. However, there was no statistically significant difference between chemical shift imaging techniques at 1.5 T and 3 T.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Proton (¹H) NMR: Chemical Shift
Absorption signals of all the protium nuclei...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
NMR Spectroscopy: Chemical Shift Overview
For instance, the proton...
Inductive Effects on Chemical Shift: Overview
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...