The effect of blue thermal treatment on endodontic instruments and apical debris extrusion during retreatment
1Department of Endodontics, Faculty of Dentistry, Kırıkkale University, Kırıkkale, Turkey.
Aim:
To determine the effect of blue thermal treatment on Reciproc (VDW, Munich, Germany) endodontic instruments and the amount of apically extruded debris during retreatment procedures.
Methodology:
Thirty extracted mandibular molar teeth having mesial roots with a degree of curvature less than 20° and having an initial apical size equivalent to a size 10 K-file were selected. The mesial roots of the teeth were removed from the cementoenamel junction to obtain a 15-mm root length. The mesiobuccal canals were prepared to size F2 using the ProTaper Universal system (Dentsply Sirona, Ballaigues, Switzerland), filled with gutta-percha and 2Seal (VDW) using the lateral compaction technique and then randomly divided into two groups (n = 15). The root fillings were removed with one of the following instruments using a crown-down preparation technique: M-Wire Reciproc or Reciproc Blue (both VDW). Apically extruded debris was collected in pre-weighed Eppendorf tubes. The Eppendorf tubes were then stored in an incubator at 70 °C for five days to evaporate the distilled water. The data were analysed using the Mann-Whitney U test (P = 0.05).
Results:
Reciproc Blue (1.42 ± 0.4491 mg) extruded significantly less debris apically than M-Wire Reciproc (2.56 ± 1.0232 mg) (P < 0.05).
Conclusions:
Blue thermal treatment of Reciproc instruments was associated with less debris extrusion during retreatment procedures.
Related Concept Videos
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Instrument Transformers
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Uncertainty in Measurement: Reading Instruments
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55...