Intra-Abdominal Adipose Tissue Quantification by Alternative Versus Reference Methods: A Systematic Review and
Jessica Murphy1,2,3, Simon L Bacon1,3,4, José A Morais1,5,6
1Department of Health, Kinesiology and Applied Physiology, Concordia University, Montreal, Quebec, Canada.
This meta-analysis found that ultrasound and DXA have minimal bias for measuring intra-abdominal adipose tissue (IAAT) compared to CT/MRI. However, wide limits of agreement suggest caution for clinical use of these alternative IAAT measurement methods.
Area of Science:
- Medical Imaging
- Body Composition Analysis
- Metabolic Health
Background:
- Accurate quantification of intra-abdominal adipose tissue (IAAT) is crucial for assessing metabolic disease risk.
- Computed tomography (CT) and magnetic resonance imaging (MRI) are reference standards for IAAT measurement but are costly and have limited accessibility.
- Alternative methods for IAAT assessment are needed for broader clinical and research applications.
Purpose of the Study:
- To evaluate the agreement between IAAT measurements obtained by alternative methods (ultrasound, bioelectrical impedance analysis, dual-energy x-ray absorptiometry) and the reference standards (CT and MRI).
Main Methods:
- A systematic literature search of MEDLINE and EMBASE was conducted to identify relevant studies.
- A meta-analysis using a random-effects model was performed to pool mean differences and 95% limits of agreement (LoA) between methods.
- Twenty-four studies employing four comparator methods for IAAT quantification were included.
Main Results:
- Ultrasound showed a pooled mean difference of -0.3 cm with wide LoA (-3.4 to 3.2 cm).
- Bioelectrical impedance analysis demonstrated a mean difference of -11.6 cm² (LoA: -43.1 to 19.9 cm²), indicating systematic underestimation.
- Dual-energy x-ray absorptiometry (DXA) yielded mean differences of 8.1 cm² (LoA: -98.9 to 115.1 cm²) for area and 10 cm³ (LoA: -280 to 300 cm³) for volume.
Conclusions:
- Ultrasound and DXA exhibit minimal bias when measuring IAAT compared to CT or MRI.
- Bioelectrical impedance analysis systematically underestimates IAAT.
- The broad limits of agreement for most comparator methods, except DXA for IAAT volume, necessitate further optimization for reliable clinical and research use.
More Related Videos
Related Concept Videos
Systematic Sampling Method
Systematic sampling is one of the simplest methods...
Area Computation by the Alternative Coordinate Method
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
In Vitro Drug Dissolution: Alternative Methods
Alternative RNA Splicing
There are five types of alternative RNA splicing that vary in the ways the pre-mRNA segments are removed or retained in the mature mRNA. The first...