Related Experiment Video
Updated: Jan 24, 2026

Preparation and In Vitro Characterization of Dendrimer-based Contrast Agents for Magnetic Resonance Imaging
Published on: December 4, 2016
Hypoxia-targeting dendritic MRI contrast agent based on internally hydroxy dendrimer for tumor imaging
Yuxin Han1, Xiaoxuan Zhou1, Yue Qian2
1Department of Radiology, Sir Run Run Shaw Hospital (SRRSH) of School of Medicine, Zhejiang University, Hangzhou, Zhejiang, 310027, China; Key Laboratory of Biomass Chemical Engineering of Ministry of Education, Center for Bionanoengineering, and Department of Chemical and Biological Engineering, Zhejiang University, Hangzhou, Zhejiang, 310027, China.
Abstract:
Hypoxia is one of the critical features in solid tumors, and hypoxia-targeting contrast agents (CAs) could greatly enhance the magnetic resonance imaging (MRI) of tumors by increasing its specificity and providing more diagnosis information. In this article, an internally hydroxy dendrimer of high molecular weight was facilely synthesized by "epoxy-amine" and "thiol-ene" reactions with a β-cyclodextrin (β-CD) as the core, and a hypoxia-targeting dendritic contrast agent (DCA) was synthesized through conjugating Gd chelates onto the internal hydroxyl groups and grafting the hypoxia-targeting groups sulfonamides and zwitterionic groups onto the exterior groups of the dendrimer. The zwitterionic surface without disturbance from internally conjugated CAs could reduce unspecific cellular uptake by normal cells, while the hypoxia-targeting group mediate the cellular uptake by hypoxic tumor cells. The in vitro and in vivo study showed that the hypoxia-targeting DCA could be selectively uptake by hypoxic cancer cells and greatly enhance the MRI of orthotopic breast tumor in a mouse model.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Internal Receptors
Hypoxia
Types of Hypoxia
There are four primary types of hypoxia, each resulting from a different cause:
1. Anemic hypoxia: This type occurs due to insufficient oxygen delivery caused by a lack of red blood cells (RBCs) or RBCs with abnormal or...
Internal Energy
Internal Energy
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...

