Related Experiment Video
Updated: Jan 24, 2026

Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
Aortic annulus angulation does not attenuate procedural success of transcatheter aortic valve replacement using a
Giuseppe D'Ancona1, Stephan Kische2, Mohamed El-Mawardy3
1Department of Cardiology, Vivantes Klinikum Im Friedrichshain Und Am Urban, Berlin, Germany. rgea@hotmail.com.
Abstract:
The objectives of the study were to evaluate the impact of aortic angulation (AA) on success of transcatheter aortic valve replacement (TAVR) with a new generation self-expandable prosthesis (Medtronic Evolut R®). Specific anatomical conditions, such as for example the presence of a horizontal aorta with elevated AA, have seemed to pose a significant challenge for the correct positioning and consequent functioning of self-expandable TAVR prostheses. We assessed 146 patients treated with Evolut R. AA was measured at computed tomography and two groups were identified using as cutoff the mean AA value. Acute outcomes were collected and compared. AA mean value was 49.6 ± 9.4° (AA ≥ 50°: 76 and AA < 50°: 70 patients). Risk profile (Logistic euroSCORE: AA ≥ 50°: 15.7; 75% IQR: 11.1-22.1 vs. AA < 50°: 14.7; 75% IQR: 10.7-24.0; p = 0.8) was equivalent. Perioperative results were similar: valve resheathing (AA ≥ 50°: 21.0% vs. AA < 50°: 24.2%; p = 0.6), recapturing (AA ≥ 50°: 19.7% vs. AA < 50°: 25.7%; p = 0.3), fluoroscopy time (AA ≥ 50°: 11.1 IQR: 8.6-17.0 min. vs. AA < 50°: 11.0 IQR: 8.0-15.7 min.; p = 0.9), and contrast agent use (AA ≥ 50°: 99.0 ± 41.8 ml. vs. AA < 50°: 104.2 ± 38.5 ml.; p = 0.4). At discharge, moderate paravalvular leak was present in 8/76 (10.5%) of the AA ≥ 50° and 6/70 (8.6%) of the AA < 50° (p = 0.7) patients. Severe paravalvular leak, implantation of a second valve, and/or conversion to surgery did not occur. Early safety (AA ≥ 50°: 7.8% vs. AA < 50°: 5.7%; p = 0.6) was similar in the two groups. AA did not affect procedural outcomes and valve performance of the Evolut R prosthesis.
More Related Videos
14:14Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Related Concept Videos
Aortic Regurgitation I: Introduction
Aortic Regurgitation III: Medical Management
Aortic Regurgitation IV: Nursing Management
Ecological Succession
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Transcription Attenuation in Prokaryotes
There are several different mechanisms used to attenuate transcription. In ribosome mediated...