Fast and High-Resolution Three-Dimensional Hybrid-Domain Photoacoustic Imaging Incorporating Analytical-Focused Transducer Beam Amplitude
Related Experiment Video
Updated: Jan 24, 2026

Three-dimensional Optical-resolution Photoacoustic Microscopy
Published on: May 3, 2011
Abstract:
Recently, many reconstruction methods have been developed to improve the lateral resolution of acoustic-resolution photoacoustic microscopy (ARPAM) in out-of-focus regions. Though these methods enhance image resolution to some extent, they require advanced computational hardware and large computational time, especially for three-dimensional (3-D) cases. However, some methods do not consider the finite size of a transducer, while others employ numerical discretization to build a focused transducer model that is less efficient and accurate. To overcome these problems, we propose a 3-D ARPAM imaging reconstruction method with high precision, high efficiency, and low memory cost. It inherits the framework of model-based reconstructions and incorporates the forward acoustic model in the hybrid domain. This hybrid-domain acoustic model promotes an analytical solution to establish a focused transducer model. Furthermore, the non-uniform fast Fourier transform (NUFFT) and deconvolution methods are introduced to reduce the required computational time and memory volume for 3-D reconstructions. According to the experimental results reconstructed by the proposed method, the lateral resolution of an ARPAM image recorded by a 20-MHz focused transducer (NA 0.393) can reach 88.39 [Formula: see text]. This resolution exceeds the diffraction limitation of the focused transducer ( [Formula: see text]). When reconstructing a 3-D image with 200×200×150 pixels, the proposed method takes only 8.15 s using a laptop loaded with Intel Core i7-8550U CPU at 1.8 GHz and 1.06-GB memory.
More Related Videos
Related Concept Videos
Conservation of Protein Domains Over Different Proteins
A limited set of protein domains often duplicate and recombine during evolution. These domains can be organized in different combinations to...
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Hybrid Zones
Development of Analytical Methods
Hybridization of Atomic Orbitals I

