Validity of energy expenditure estimation methods during 10 days of military training
Andrew G Siddall1, Steven D Powell1, Sarah C Needham-Beck1
1Occupational Performance Research Group, University of Chichester, Chichester, UK.
Abstract:
Wearable physical activity (PA) monitors have improved the ability to estimate free-living total energy expenditure (TEE) but their application during arduous military training alongside more well-established research methods has not been widely documented. This study aimed to assess the validity of two wrist-worn activity monitors and a PA log against doubly labeled water (DLW) during British Army Officer Cadet (OC) training. For 10 days of training, twenty (10 male and 10 female) OCs (mean ± SD: age 23 ± 2 years, height 1.74 ± 0.09 m, body mass 77.0 ± 9.3 kg) wore one research-grade accelerometer (GENEActiv, Cambridge, UK) on the dominant wrist, wore one commercially available monitor (Fitbit SURGE, USA) on the non-dominant wrist, and completed a self-report PA log. Immediately prior to this 10-day period, participants consumed a bolus of DLW and provided daily urine samples, which were analyzed by mass spectrometry to determine TEE. Bivariate correlations and limits of agreement (LoA) were employed to compare TEE from each estimation method to DLW. Average daily TEE from DLW was 4112 ± 652 kcal·day-1 against which the GENEActiv showed near identical average TEE (mean bias ± LoA: -15 ± 851 kcal. day-1 ) while Fitbit tended to underestimate (-656 ± 683 kcal·day-1 ) and the PA log substantially overestimate (+1946 ± 1637 kcal·day-1 ). Wearable physical activity monitors provide a cheaper and more practical method for estimating free-living TEE than DLW in military settings. The GENEActiv accelerometer demonstrated good validity for assessing daily TEE and would appear suitable for use in large-scale, longitudinal military studies.
More Related Videos
06:57Determining Basal Energy Expenditure and the Capacity of Thermogenic Adipocytes to Expend Energy in Obese Mice
Published on: November 11, 2021
14:17The Portable Chemical Sterilizer PCS, D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
Related Concept Videos
Reliability and Validity
Nuclear Binding Energy
What is Energy?
Free Energy
Bond Energies and Bond Lengths
What are Estimates?
The estimate for the mean of a sample is denoted by ͞x, whereas the mean of the population is designated as μ. Further, parameters such...