Related Experiment Video
Updated: Jan 24, 2026

Ubiquitin Chain Analysis by Parallel Reaction Monitoring
Published on: June 17, 2020
An optical and non-invasive method to detect the accumulation of ubiquitin chains
Jun Imai1, Yuuta Koganezawa1, Haruka Tuzuki1
1Laboratory of Physiological Chemistry, Faculty of Pharmacy, Takasaki University of Health and Welfare, 60 Nakaorui-machi, Takasaki-shi, Gunma, 370-0033, Japan.
Abstract:
The accumulations of excess amounts of polyubiquitinated proteins are cytotoxic and frequently observed in pathologic tissue from patients of neurodegenerative diseases. Therefore, optical and non-invasive methods to detect the increase of the amounts of polyubiquitinated proteins in living cells is a promising strategy to find out symptoms and environmental cause of neurodegenerative diseases, also for identifying compounds that could inhibit gathering of polyubiquitinated proteins. Therefore, we generated a pair of fluorescent protein [Azamigreen (Azg) and Kusabiraorange (Kuo)] tagged ubiquitin on its N-terminus (Azg-Ub and Kuo-Ub) and developed an Azg/Kuo-based Fluorescence Resonance Energy Transfer (FRET) assay to estimate the amount of polyubiquitin chains in vitro and in vivo. The FRET intensity was attenuated in the presence of ubiquitin-activating enzyme inhibitor, PYR-41, indicating that both fluorescent ubiquitin is incorporated into ubiquitin chains likewise normal ubiquitin. The FRET intensity was enhanced by the addition of the proteasome inhibitor, MG-132, and was reduced in the presence of the autophagy activator Rapamycin, designating that ubiquitin chains with fluorescent ubiquitin act as the degradation signal equally with normal ubiquitin chains. In summary, the above optical methods provide powerful research tools to estimate the amounts of polyubiquitin chains in vitro and in vivo, especially non-invasively in living cells.
Related Concept Videos
Electron Transport Chains
The ETC is comprised of...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Radical Chain-Growth Polymerization: Chain Branching
The Chain Rule
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Drug Accumulation During Multiple Dosing: Repetitive IV Injections

