A Swin Transformer-Based Model for Thyroid Nodule Detection in Ultrasound Images
Published on: April 21, 2023
The Value of Elasticity Contrast Index in the Differential Diagnosis of Thyroid Solid Nodules
Zhixin Di1, Ziyao Li1, Jiawei Tian1
1Department of Ultrasound, Second Affiliated Hospital of Harbin Medical University, Harbin City.
Objectives:
To assess the clinical value of elasticity contrast index (ECI) in differentiating malignant thyroid nodules from benign ones.
Methods:
Conventional ultrasound and elastography with pulsation of the carotid artery used as the compression source were retrospectively reviewed on 175 patients (143 females and 32 males; mean ± SD age, 45.17 ± 11.45 years) with 236 solid nodules (113 malignant and 123 benign). All nodules were confirmed by fine-needle aspiration or surgery to be accurately diagnosed. Elasticity contrast index values were computed and used to quantify local stiffness contrast within a nodule as determined with elastography. Elasticity contrast index values between the malignant and benign groups were compared and then related with pathological results. Diagnostic performance of this method was evaluated with use of the receiver operating characteristic curve.
Results:
Mean ± SD ECI values for malignant thyroid nodules were significantly greater than those for benign nodules (3.67 ± 1.20 vs 1.80 ± 0.74, P < 0.01). Area under the receiver operating characteristic curve of ECI values was 0.907 (95% confidence interval, 0.867-0.948), and the best cutoff point was 2.16, leading to a sensitivity of 90.3%, specificity of 82.9%, positive predictive value of 83.7% and negative predictive value of 91.2%.
Conclusions:
Elasticity contrast index values can serve as a useful parameter in the differential diagnosis of solid thyroid nodules. With the use of ECI values, objective quantitative information on the tumor stiffness can be achieved to improve diagnostic confidence.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Metallic Solids
All metallic solids exhibit high thermal and electrical conductivity, metallic luster, and malleability....
Structures of Solids
Elasticity
The elasticity of an object can be described by a stress-strain curve, which represents the relationship between stress...
Network Covalent Solids
To break or to melt a covalent network solid, covalent bonds must be broken. Because covalent bonds are relatively strong, covalent network solids are typically...
The Thyroid Gland
The follicles have a central cavity lined by simple cuboidal to squamous epithelial cells called follicular cells. These cells produce the glycoprotein...