A Modified Sonographic Algorithm for Image Acquisition in Life-Threatening Emergencies in the Critically Ill Newborn
Published on: April 7, 2023
Four-Dimensional Ultrasound for Evaluating Newborn Cardiac Output: A Pilot Study of Healthy Infants
Lisha Lobo1, Gordon Stevenson1, Jennifer Alphonse1
1School of Women's and Children's Health, University of New South Wales, Randwick, New South Wales, Australia.
Background:
There is currently no reliable non-invasive method of measuring cardiac output in neonatal intensive care. Spatiotemporal image correlation (STIC) is a novel four-dimensional (4D) ultrasound technique that was developed to assess the foetal heart, and it may be a useful way to assess neonatal haemodynamics.
Objective:
This study aimed to evaluate the feasibility and reproducibility of determining neonatal cardiac output using STIC ultrasound in newborn infants.
Design:
Infants were recruited opportunistically from a neonatal intensive care unit and then examined by 2 independent observers. STIC was used to obtain images of the heart. End-diastolic and end-systolic ventricular volumes were measured using virtual organ computer-aided analysis (VOCAL) and used to calculate cardiac output. Reproducibility was assessed with intraclass correlation coefficients (ICC) and agreement with Bland-Altman analysis.
Results:
Twenty-four clinically stable infants of 34-43 weeks corrected gestational age were assessed. Both observers successfully acquired 4D STIC volumes in all infants. Left ventricular output showed good reproducibility, with an intra-observer ICC of 0.86 (0.69-0.94) and inter-observer ICC of 0.87 (0.70-0.95). Right ventricular output also showed good reproducibility, with an intra-observer ICC of 0.88 (0.70-95) and inter-observer ICC of 0.84 (0.63-0.93).
Conclusions:
Determining cardiac output using 4D STIC ultrasound is feasible and reproducible in well newborn infants. With further evaluation, this technique may provide valuable information about haemodynamic status in newborn infants requiring intensive care.
Related Concept Videos
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Bioavailability Study Design: Healthy Subjects Versus Patients