Related Experiment Video
Updated: Jan 24, 2026

Evaluation of the Impact of Protein Aggregation on Cellular Oxidative Stress in Yeast
Published on: June 23, 2018
Electrochemical Methodology for Evaluating Skin Oxidative Stress Status (SOSS)
Pincemail Joël1, Kaci Mouna-Messaouda2, Cheramy-Bien Jean-Paul3
1University of Liège and CHU, Department of Cardiovascular Surgery/CREDEC, Antioxidant Nutrition and Health Platform, Sart Tilman, 4000 Liège, Belgium. j.pincemail@chuliege.be.
Abstract:
For the purpose of human disease prevention, several methods have been developed, and are still developing, to assess the oxidative stress status (OSS) of individuals. In the present paper, we describe an approach based on electrochemical detection able to evaluate skin oxidative stress status (SOSS) as a PAOT (Pouvoir AntiOxydant Total)-Skin Score®. Normal reference values for the PAOT-Skin Score® were: 0-62.94 (n = 263). Intra- and inter-assay coefficients of variation were, respectively, 12.47 ± 4.29% and 7.0 ± 2.5%. Our technology showed increased skin antioxidant activity following topical application of reduced coeznyme Q10 cream or vitamin C intake as orange juice or supplements. Moreover, we found significant correlations between some blood oxidative stress biomarkers and the PAOT-Skin Score ® (-tocopherol/α-tocopherol ratio (r = 0.43, p = 0.020); copper (r = -0.42, p = 0.022); copper/zinc ratio (r = -0.49, p = 0.006), and lipid peroxides (r = -0.43, p = 0.002)). In addition to being non-invasive, the present electrochemical methodology is also not expensive, fast, and easy to use.
More Related Videos
10:21Evaluation of Hydration Status by Bioelectrical Impedance Vector Analysis in Patients with Ischemic Heart Disease Undergoing Exercise Stress Test
Published on: September 22, 2023
08:14Ecotoxicological Methodologies to Evaluate Biomarkers at Different Scales in Neotropical Anurans
Published on: April 28, 2023
Related Concept Videos
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Oxidation Numbers
Pyruvate Oxidation
First, the enzyme pyruvate dehydrogenase removes the carboxyl group from pyruvate and releases it as carbon dioxide. The stripped molecule is then oxidized and releases electrons, which are then picked up by NAD+...
Oxidation-Reduction Reactions
Marcia's Theory of Identity Status
Responses to Salt Stress