Published on: February 25, 2022
Performance analysis of the transcatheter aortic valve implantation on blood flow hemodynamics: An optical
Utku Gülan1, Harish Appa2, Pascal Corso1
1Institute for Environmental Engineering, Swiss Federal Institute of Technology Zurich, Zurich, Switzerland.
Abstract:
Cardiac implants may have a strong influence on the hemodynamics of the circulatory system. In this study, we aimed at investigating the impact of transcatheter aortic valve implantation (TAVI) devices on blood flow patterns that develop in the ascending aorta under physiological flow conditions in vitro. For this purpose, a noninvasive optical measurement tool, three-dimensional particle tracking velocimetry (3D-PTV), was used in a realistic compliant silicone aortic model. The performance and the influence of two TAVIs and one surgical valve on the aortic flow were investigated. Our results showed that valve design and materials may have a distinct influence on relevant hemodynamic properties, namely kinetic energy, production of turbulence, and shear stresses in the ascending aorta. All properties varied considerably between the different valve models. We found that the total aortic regurgitation composed of the closing volume, transvalvular and paravalvular leakages varied for the three valves investigated. Furthermore, peak mean kinetic energy (MKE) ranged from 61 to 116 J/m3 , whereas peak turbulent kinetic energy (TKE) ranged from 23 to 36 J/m3 . The analysis of shear showed that all the three studied devices had minimal overall risk for thrombus formation. We conclude that the characteristics and material designs of TAVI devices have strong influences on the hemodynamics in the ascending aorta.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
14:14Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Related Concept Videos
Blood Flow
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....
Drug Product Performance: In Vitro–In Vivo Correlation
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to...
Performing a Simple Data Analysis using MS-Excel Function
SUM: This function calculates the total sum of a range of values. It's the foundation for aggregating data, essential for determining overall trends and totals in datasets.
AVERAGE: It computes the mean value of a given set of numbers, providing a quick insight into the central...