Related Experiment Video
Updated: Jan 24, 2026

Guided Endodontics: Three-Dimensional Planning and Template-Aided Preparation of Endodontic Access Cavities
Published on: May 24, 2022
Penetration of bioceramic and epoxy-resin endodontic cements into lateral canals
George Táccio de Miranda Candeiro1, Amanda Bezerra Lavor2, Ilana Thaís de Freitas Lima1
1Centro Universitário Christus - Unichristus, Post-graduation Program of Dental Sciences, Fortaleza, CE, Brazil.
Abstract:
The aim of the present study was to assess the penetration capacity of two endodontic cements, Endosequence BC Sealer and AH Plus, in artificial lateral canals. Twenty-six two-rooted, maxillary first premolars were instrumented to size 40.06 using K3 files. In each root, six lateral canals of two diameters (0.06 and 0.10 mm) were created with a working length of 2, 4, and 6 mm. The specimens were randomly divided into two groups according to the endodontic cement to be used (Endosequence BC Sealer and AH Plus) and obturated by the single-cone technique. The specimens were imaged by digital periapical radiography and scores from 0 to 4 were attributed according to the degree of penetration by sealers into the lateral canals. Data were analyzed statistically by Kruskal-Wallis and Student-Newman-Keuls tests, and a significance level of p < 0.05 was adopted. No significant difference was observed between the two endodontic cements used to fill the simulated lateral canals (p > 0.05). The diameter of lateral canals only influenced the capacity of the Endosequence BC Sealer in filling the canals, and presented greater penetration in the lateral canals of diameter 0.10 mm (p < 0.05). We concluded that the bioceramic endodontic cement Endosequence BC Sealer presented similar ability as AH Plus to fill simulated lateral canals.
More Related Videos
Related Concept Videos
Hydration of Cement
Soundness of Cement
Portland Cement
Fineness of Cement
Direct...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Types of Cement I
Type I (Ordinary Portland Cement) is widely used for general construction where special properties are not required. It has moderate sulfate resistance and heat of hydration.
Type II (Modified Cement) offers moderate resistance to sulfate attack and a lower rate of heat development compared to Type I. It is suitable for structures in...