Related Experiment Video
Updated: Jan 24, 2026

A Microfluidic Device for Quantifying Bacterial Chemotaxis in Stable Concentration Gradients
Published on: April 19, 2010
Parameter Selection for a Microvolume Electrochemical Escherichia coli Detector for Pairing with a Concentration
Evelina J Y Han1, Kannan Palanisamy2, Jamie Hinks3
1Singapore Centre for Environmental Life Sciences Engineering (SCELSE), Nanyang Technological University, 60 Nanyang Drive, Singapore 637551, Singapore. hjyeve@gmail.com.
Abstract:
Waterborne infections are responsible for health problems worldwide and their prompt and sensitive detection in recreational and potable water is of great importance. Bacterial identification and enumeration in water samples ensures water is safe for its intended use. Culture-based methods can be time consuming and are usually performed offsite. There is a need to for automated and distributed at-source detectors for water quality monitoring. Herein we demonstrate a microvolume Escherichia coli (E. coli) detector based on a screen printed electrode (SPE) bioelectroanalytical system and explore to what extent performance can be improved by coupling it with a filtration device. To confidently benchmark detector performance, we applied a statistical assessment method to target optimal detection of a simulated concentrated sample. Our aim was to arrive at a holistic understanding of device performance and to demonstrate system improvements based on these insights. The best achievable detection time for a simulated 1 CFU mL-1 sample was 4.3 (±0.6) h assuming no loss of performance in the filtration step. The real filtered samples fell short of this, extending detection time to 16-18 h. The loss in performance is likely to arise from stress imposed by the filtration step which inhibited microbial growth rates.
Related Concept Videos
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Concentration Cells
Consider the following voltaic cell:
DNA Base Pairing
VSEPR Theory and the Effect of Lone Pairs
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...