Related Experiment Video
Updated: Jan 24, 2026

In vivo Imaging of Optic Nerve Fiber Integrity by Contrast-Enhanced MRI in Mice
Published on: July 22, 2014
Contrast leakage distant from the hematoma in patients with spontaneous ICH: A 7 T MRI study
Wilmar Mt Jolink1, Arjen Lindenholz2, Ellis S van Etten3
1Department of Neurology and Neurosurgery, Brain Center Rudolf Magnus, University Medical Center Utrecht, Utrecht, The Netherlands.
Abstract:
Disruption of the blood-brain barrier (BBB) might play a role in the pathophysiology of cerebral small vessel disease-related ICH. The aim of this study was to assess presence and extent of contrast agent leakage distant from the hematoma as a marker of BBB disruption in patients with spontaneous ICH. We prospectively performed 7 tesla MRI in adult patients with spontaneous ICH and assessed contrast leakage distant from the hematoma on 3D FLAIR images. Thirty-one patients were included (mean age 60 years, 29% women). Median time between ICH and MRI was 20 days (IQR 9-67 days). Seventeen patients (54%; seven lobar, nine deep, one infratentorial ICH) had contrast leakage, located cortical in 16 and cortical and deep in one patient. Patients with contrast leakage more often had lobar cerebral microbleeds (CMBs; 77%) than those without (36%; RR 2.5, 95% CI 1.1-5.7) and a higher number of lobar CMBs (patients with contrast leakage: median 2, IQR 1-8 versus those without: median 0, IQR 0-2; p = 0.02). This study shows that contrast leakage distant from the hematoma is common in days to weeks after spontaneous ICH. It is located predominantly cortical and related to lobar CMBs and therefore possibly to cerebral amyloid angiopathy.
Related Concept Videos
Spontaneity
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Spontaneous and Induced Mutations
Bioavailability Study Design: Healthy Subjects Versus Patients
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...

