Related Experiment Video
Updated: Jan 24, 2026

Intrathecal Application of a Fluorescent Dye for the Identification of Cerebrospinal Fluid Leaks in Cochlear Malformation
Published on: February 29, 2020
Bone Morphogenetic Protein in the Repair of Cerebrospinal Fluid Leak after Transsphenoidal Surgery
Dejan Slavnic1, Richard Floyd Cook1, Matthew Bahoura2
1Department of Surgery, Providence-Providence Park Hospitals, College of Human Medicine, Michigan State University, East Lansing, Southfield, Michigan, USA.
Background:
Recurrent cerebrospinal fluid (CSF) leak carries significant morbidity. We sought to demonstrate that bone morphogenetic protein (BMP) use is effective and safe for the repair of recurrent CSF leak after a transsphenoidal pituitary tumor resection (TSPTR).
Materials And Methods:
We reviewed charts and radiographic data of consecutive patients who underwent BMP repair of recurrent CSF leak after TSPTR from January 2010 to June 2015 and who failed previous multilayer closure. We detailed the technique for constructing and placing a BMP-DuraGen patch for the repair. The primary variables include postoperative computed tomography/magnetic resonance imaging (CT/MRI) evidence of ectopic bone growth or inflammation, newly diagnosed systemic neoplasm within 1 year, and recurrent CSF leak. Secondary outcome is the length of stay after BMP repair. All patients were followed up radiographically and through phone interview.
Results:
Four patients underwent BMP repair of recurrent CSF leak after TSPTR. The average postoperative CT/MRI interval was 22 months. Postoperative CT/MRI revealed no ectopic bone formation or inflammatory changes around the site of BMP application. There was no recurrence of CSF leak or newly diagnosed neoplasm from both chart review and phone interview.
Conclusions:
We demonstrate that the use of BMP is a safe and an effective treatment in the repair of recurrent CSF leaks after TSPTR.
Related Concept Videos
Cerebrospinal Fluid
CSF Production
CSF is produced mainly in the choroid plexus, a network of capillaries and ependymal cells located within the ventricular system of the brain....
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Mismatch Repair
Nucleotide Excision Repair
Overview of DNA Repair
Chemically...
Base Excision Repair
The first step of...