Related Experiment Video
Updated: Jan 24, 2026

Proximal Cadaveric Femur Preparation for Fracture Strength Testing and Quantitative CT-based Finite Element Analysis
Published on: March 11, 2017
Previous Damage Accumulation Can Influence Femoral Fracture Strength: A Finite Element Study
Ifaz T Haider1, Hanspeter Frei1
1Department of Mechanical and Aerospace Engineering, Carleton University, 3135 Mackenzie Building, 1125 Colonel By Dr, Ottawa, ON, K1S 5B6, Canada.
Abstract:
To manage osteoporotic hip fracture risk, it is necessary to understand failure mechanisms of bone at both the material and organ level. The structural response of bone is dependent on load history. Repeated loading causes progressive microstructural cracking, resulting in reduced apparent-level stiffness and, if damage is significant, reductions to peak load bearing capability. However, the effect of previous damage accumulation has not been well explored at the organ level. It was hypothesized that femoral fracture load and fracture pattern may be sensitive to damage accumulation from previous loading events. Six cadaveric specimens were used to develop patient specific finite element (FE) models from quantitative tomographic (qCT) scans. Material properties were assigned from qCT intensity at each element location, and damage evolution was predicted using a previously validated quasi-brittle FE model. Three scenarios were investigated: stumble followed by another stumble (S-S), fall followed by another fall (F-F), and stumble followed by a fall (S-F). Fracture load and pattern were compared to FE predictions for a single stumble (S) or single fall (F) loading event. Most specimens were resilient to accumulated damage, showing little (<5%) change in fracture load from the multiple-load scenarios (S-S, F-F, and S-F) compared to an equivalent single load scenario (S or F). Only one specimen demonstrated moderate (5-15%) reductions in strength from all three multiple-load scenarios. However, two specimens experienced moderate (20-30%) increase in fracture load in some load cases. In these cases, initial damage caused the load to be more evenly distributed upon subsequent loading events. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 37:2197-2203, 2019.
Related Concept Videos
Acid Strength and Molecular Structure
In the absence of any leveling effect, the acid strength of binary compounds of hydrogen with nonmetals (A) increases as the H-A bond strength decreases down a group in the periodic table. For group 17, the order of increasing acidity is HF < HCl < HBr < HI. Likewise, for group 16, the order of increasing acid strength is H2O < H2S < H2Se < H2Te. Across a row in the periodic table, the acid strength of binary hydrogen compounds increases with increasing...
Elements and Compounds
Elements
Elements are classified as atomic or molecular based on the nature of their basic units. They are unique forms of matter with specific chemical and physical properties that cannot break down into smaller substances by ordinary chemical reactions. There...
Periodic Classification of the Elements
Classification of Elements and Compounds
Compounds are pure substances composed of two or more elements in fixed, definite proportions. Compounds are classified as ionic or molecular (covalent) based on the bonds...
Key Elements for Plant Nutrition
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...

