A Primary Computational Fluid Dynamics Study of Pre- and Post-TEVAR With Intentional Left Subclavian Artery Coverage
Yonghui Qiao1, Jianren Fan2, Ying Ding3
1State Key Laboratory of Clean Energy Utilization,Zhejiang University,38 Zheda Road,Hangzhou 310027, Chinae-mail: yhqiao@zju.edu.cn.
Abstract:
The impact of left subclavian artery (LSA) coverage during thoracic endovascular aortic repair (TEVAR) on the circulatory system is not fully understood. Here, we coupled a single-phase non-Newtonian model with fluid-structure interaction (FSI) technique to simulate blood flow in an acute type B aortic dissection. Three-element Windkessel model was implemented to reproduce physiological pressure waves, where a new workflow was designed to determine model parameters with the absence of measured data. Simulations were carried out in three geometric models to demonstrate the consequence of TEVAR with the LSA coverage; case A: pre-TEVAR aorta; case B: post-TEVAR aorta with the disappearance of LSA; case C: post-TEVAR aorta with virtually adding LSA. Results show that the blood flow through the compressed true lumen is only 8.43%, which may lead to ischemia in related organs. After TEVAR, the wall pressure on the stented segment increases and blood flow in the supra-aortic branches and true lumen is improved. Meantime, the average deformation of the aorta is obviously reduced due to the implantation of the stent graft. After virtually adding LSA, significant changes in the distribution of blood flow and two indices based on wall shear stress are observed. Moreover, the movement of residual false lumen becomes stable, which could contribute to patient recovery. Overall, this study quantitatively evaluates the efficacy of TEVAR for acute type B aortic dissection and demonstrates that the coverage of LSA has a considerable impact on the important hemodynamic parameters.
More Related Videos
Related Concept Videos
Types of Fluids
In contrast, non-Newtonian fluids do not follow Newton's law of viscosity, and...
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Imaging Studies III: Computed Tomography
pre-mRNA Processing
Once about 20-40 ribonucleotides have been joined together by RNA polymerase, a group of enzymes adds a “cap” to the 5’ end of the growing transcript. In this process, a 5’ phosphate is replaced by modified guanosine that has a methyl group attached to it (7-Methyl...
Pre-mRNA Processing: Modification of pre-mRNA Ends
Once about 20-40 ribonucleotides have been joined together by RNA polymerase, a group of enzymes adds a cap to the 5' end of the growing transcript. In this process, a 5' phosphate is replaced by modified guanosine that has a methyl group attached (7-methyl guanosine). This 5' cap helps...
The Fluid Mosaic Model