Related Experiment Video
Updated: Jan 24, 2026

Clean Sampling and Analysis of River and Estuarine Waters for Trace Metal Studies
Published on: July 1, 2016
Microbial risk associated with CSOs upstream of drinking water sources in a transboundary river using hydrodynamic
Milad Taghipour1, Ahmad Shakibaeinia1, Émile Sylvestre2
1Civil, Geological and Mining Engineering, Polytechnique Montréal, C.P.6079, Station Centre-ville, Montréal, Québec H3C 3A7, Canada.
Abstract:
Urban source water protection planning requires the characterization of sources of contamination upstream of drinking water intakes. Elevated pathogen concentrations following Combined Sewer Overflows (CSOs) represent a threat to human health. Quantifying peak pathogen concentrations at the intakes of drinking water plants is a challenge due to the variability of CSO occurrences and uncertainties with regards to the fate and transport mechanisms from discharge points to source water supplies. Here, a two-dimensional deterministic hydrodynamic and water quality model is used to study the fluvial contaminant transport and the impacts of the upstream CSO discharges on the downstream concentrations of Escherichia coli in the raw water supply of two drinking water plants, located on a large river. CSO dynamic loading characteristics were considered for a variety of discharges. As a result of limited Cryptosporidium data, a probability distribution of the ratio of E. coli to Cryptosporidium based on historical data was used to estimate microbial risk from simulated CSO-induced E. coli concentrations. During optimal operational performance of the plants, the daily risk target was met (based on the mean concentration during the peak) for 80% to 90% of CSO events. For suboptimal performance of the plants, these values dropped to 40% to 55%. Mean annual microbial risk following CSO discharge events was more dependent on treatment performance rather than the number of CSO occurrences. The effect of CSO-associated short term risk on the mean annual risk is largely dependent on the treatment performance as well as representativeness of the baseline condition at the intakes, demonstrating the need for assessment of treatment efficacy. The results of this study will enable water utilities and managers with a tool to investigate the potential alternatives in reducing the microbial risk associated with CSOs.
More Related Videos
11:29Cost-effective Method for Microbial Source Tracking Using Specific Human and Animal Viruses
Published on: December 3, 2011
10:48EPA Method 1615. Measurement of Enterovirus and Norovirus Occurrence in Water by Culture and RT-qPCR. I. Collection of Virus Samples
Published on: March 28, 2015
Related Concept Videos
Quality of Water
Testing Water Quality
States of Water
Water freezes when the intermolecular forces are greater than the kinetic energy. Unlike most other substances, water is less dense in its solid state than in its liquid state. This is because each water molecule can form...
The Water Cycle
Water and Mineral Acquisition
Effect of Sea Water on Concrete
Concrete in areas between tide marks,...