Micro cone beam computed tomography for sensitive assessment of radiation-induced late lung toxicity in preclinical
D van Berlo1, A Khmelinskii2, A Gasparini2
1Division of Cell Biology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
Background And Purpose:
Preclinical models are much needed to assess the effect of novel radio-sensitizers or mitigators on radiation dose limiting lung toxicity. Albeit showing radiation-induced lung pathologies, current mouse models lack the sensitivity to do so. Using micro image-guided radiotherapy (µIGRT) techniques, we aimed to establish murine models which enable the sensitive detection of lung damage aggravation and characterized functional, radiological and histological responses.
Materials And Methods:
Right lungs of C57Bl/6J mice were irradiated using µIGRT with doses from 15 to 27 Gy and with 21 Gy and cisplatin as a radio-sensitizer in a second study. Mice were sacrificed for histological and pathological assessment at different time-points post-IR. Lung density was determined using the integrated micro cone-beam CT (µCBCT). Lung function was measured by double-chamber-plethysmography.
Results:
µIGRT resulted in accurate deposition of the radiation dose in the right lung only as determined by ɣH2AX staining. Lung fibrosis was confirmed by pathological assessments and increased significantly at 21 Gy as determined by automated quantification of histochemical analyses. Lung function was affected in a dose-dependent manner. µCBCT-determined lung densities increased significantly over time in the irradiated lungs and showed a strong radiation dose-dependence. Importantly, the µCBCT analyses allowed the detection of additional lung damage caused by 3 Gy dose increments or by the combination with cisplatin.
Conclusion:
µCBCT after right lung µIGRT enables the sensitive detection of effects inflicted by relative small dose increments or radio-sensitizers. Our preclinical model therefore facilitates the determination of lung damage exacerbation for the safety assessment of novel RT-drug combinations.
More Related Videos
06:21Diffuse Optical Spectroscopy for the Quantitative Assessment of Acute Ionizing Radiation Induced Skin Toxicity Using a Mouse Model
Published on: May 27, 2016
03:38Unilateral Lung Volume Analysis Using Micro-CT for Enhanced Assessment of Pulmonary Fibrosis in Preclinical Models
Published on: June 20, 2025
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Biological Effects of Radiation
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Induced-fit Model
Enzymes exhibit substrate specificity, meaning that they can only bind to certain substrates. This is mainly determined by the shape and chemical...
Radiation: Applications
The average...