3D optical detection in radiodosimetry: EasyDosit hydrogel characterization
Jérémy Coulaud1, Véronique Brumas1, Patrick Sharrock1
1SIMAD LU 50, Université Toulouse 3 Paul Sabatier, avenue Georges Pompidou, 81004 Castres, France.
Abstract:
In this study the spectrophotometric behaviour of gelatin-based hydrogels, in the presence and absence of dyes, was studied. The aim was to formulate equivalent-tissue phantoms to be used as 3D-dosimeter, suitable for Optical Computed Tomography (OCT). The hydrogels show good transparency and good stability of baseline optical density and, in the presence of dye, the response of optical density as a function of concentration was higher than in aqueous solution. The hydrogels were formulated in order to reduce the diffusion of the image of the irradiated field over time and to have stable fantoms as a function of time. To this purpose, the diffusion coefficients of two dyes, Bromophenol Blue (BPB) and Bromocresol Green (BCG), were determined as a function of the hydrogel chemical composition. As comparison, in some experiments Xylenol Orange (XO) was used. In particular, the presence of sucrose, as thickener, can reduce to almost half BPB mobility. In conclusion, it was shown that optical properties and controlled dye diffusion in gelatin-based hydrogels could allow using them as 3D-dosimeter for optical detection.
Related Concept Videos
Properties of Enantiomers and Optical Activity
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Detection of Gross Error: The Q Test
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...