Related Experiment Video
Updated: Jan 24, 2026

Designing CAD/CAM Surgical Guides for Maxillary Reconstruction Using an In-house Approach
Published on: August 24, 2018
Viscoelastic stability of pre-cured resin-composite CAD/CAM structures
Rasha A Alamoush1, Julian D Satterthwaite2, Nick Silikas2
1Dentistry, School of Medical Sciences, The University of Manchester, Manchester, UK; Prosthodontic Department, School of Dentistry, University of Jordan, Amman, Jordan.
Objectives:
To study the effect of water storage (3 months) on the creep deformation and recovery of CAD/CAM composite materials to determine their viscoelastic stability.
Materials And Methods:
Five CAD/CAM composite blocks, with increasing filler loading, and one polymer-infiltrated ceramic network (PICN) were studied. Six specimens of each material were separated into two groups (n=3) according to their storage conditions (24 h dry storage at 23°C versus 3 months storage in 37°C distilled water). A constant static compressive stress of 20 MPa was applied on each specimen via a loading pin for 2 h followed by unloading and monitoring strain recovery for a further period of 2 h. The maximum creep-strain (%) and permanent set (%) were recorded. Data were analysed via two-way ANOVA followed by one-way ANOVA and Bonferroni post hoc tests (<0.05) for comparisons between the materials. Homogeneity of variance was calculated via Levene's statistics.
Results:
The maximum creep strain after 24 h dry ranged from 0.45% to 1.09% and increased after 3-month storage in distilled water to between 0.71% and 1.85%. The permanent set after 24 h dry storage ranged from 0.033% to 0.15% and increased after 3-month water storage to between 0.087% and 0.18%. The maximum creep strain also reduced with increasing filler loading.
Significance:
The PICN material exhibited superior dimensional stability to all of the pre-cured resin composite blocks in both storage conditions with deformation being predominantly elastic rather than viscoelastic. Notwithstanding, two of the resin-matrix composite blocks approached the PICN performance, when dry, but less so after water storage.
More Related Videos
16:30Application of Light-cured Dental Adhesive Resin for Mounting Electrodes or Microdialysis Probes in Chronic Experiments
Published on: July 30, 2007
05:42Detection and Removal of Tooth-Colored Composite Resin Using the Fluorescence-Aided Identification Technique
Published on: July 27, 2022
Related Concept Videos
Stability of structures
C4 Pathway and CAM
C4 Pathway
The C4 pathway is used by plants such as...
Chromatin Structure Regulates pre-mRNA Processing
The chromatin structure, especially...
Sperm Structure and Semen Composition
Curing of Concrete
Curing Methods