Related Experiment Video
Updated: Jan 24, 2026

Novel and Innovative Hybrid Technique for Type A Aortic Dissection
Published on: March 28, 2025
Five-year results from the Study of Thoracic Aortic Type B Dissection Using Endoluminal Repair (STABLE I) study of
Joseph V Lombardi1, Richard P Cambria2, Christoph A Nienaber3
1Division of Vascular and Endovascular Surgery, Cooper University Hospital, Camden, NJ.
Insights
The STABLE I study shows endovascular repair using a Zenith stent graft is safe and effective for complicated type B aortic dissection, with similar outcomes in acute and non-acute cases over five years.
Area of Science:
- Cardiovascular Surgery
- Endovascular Interventions
- Aortic Disease Management
Background:
- Complicated type B aortic dissection poses significant risks.
- Endovascular repair offers a less invasive treatment option.
- Long-term outcomes of specific devices require evaluation.
Purpose of the Study:
- To report final 5-year outcomes of the STABLE I study.
- To evaluate the Zenith Dissection Endovascular System for type B aortic dissection.
- To compare outcomes between acute and non-acute treatment phases.
Main Methods:
- Prospective, single-arm, multicenter study.
- 86 patients with complicated type B aortic dissection treated with Zenith stent graft.
- 5-year clinical and imaging follow-up.
Main Results:
- Low 30-day all-cause mortality (5.5% acute, 3.2% non-acute).
- 5-year freedom from all-cause mortality: 79.9% (acute) vs. 70.1% (non-acute).
- High rates of false lumen thrombosis (74.1% acute, 58.8% non-acute) and favorable aortic remodeling observed.
Conclusions:
- Endovascular repair with the Zenith system is safe and effective for complicated type B aortic dissection.
- Similar clinical outcomes and aortic remodeling in acute and non-acute patient cohorts.
- The composite device design demonstrated favorable long-term results.
Objective:
We report the final 5-year results from the Study of Thoracic Aortic Type B Dissection Using Endoluminal Repair (STABLE I) study, a prospective, single-arm, multicenter study of the Zenith Dissection Endovascular System (William Cook Europe, Aps, Bjaeverskov, Denmark), a pathology-specific device comprising a proximal stent graft with barbs and a distal bare stainless steel stent for the treatment of patients with complicated type B aortic dissection.
Methods:
The study prospectively enrolled 86 patients (mean age, 59 years; 73% male) at sites in the United States, Europe, and Australia from 2007 to 2012. Treatment occurred during the acute phase (≤14 days after symptom onset) in 55 patients and during the nonacute phase (>14 days; all treated ≤90 days) in 31 patients. Five-year clinical and imaging follow-up was available for 88.5% of eligible patients.
Results:
The 30-day all-cause mortality rate was 5.5% (3 of 55) for acute and 3.2% (1 of 31) for nonacute patients (P > .99). The 5-year freedom from all-cause mortality was 79.9% ± 6.2% for acute and 70.1% ± 8.4% for nonacute patients (log-rank test, P = .40). The 5-year freedom from dissection-related mortality (including deaths of indeterminate relatedness to dissection repair) was 83.9% ± 5.9% for acute and 90.1% ± 5.9% for nonacute patients (log-rank test, P = .55). Complete false lumen thrombosis in the thoracic aorta increased over time and was observed in 74.1% of acute and in 58.8% of nonacute patients at 5 years. From preprocedure through 5 years, there was an overall increase in true lumen diameter and a concomitant decrease in false lumen diameter in both acute and nonacute patients at the level of the largest diameter in both the thoracic and abdominal aortas. At 5 years, 65.5% of acute and 81.3% of nonacute patients exhibited a stable or shrinking transaortic diameter in the thoracic aorta, and 48.3% of acute and 76.5% of nonacute patients had a stable or shrinking transaortic diameter in the abdominal aorta. Freedom from secondary intervention at 5 years was 65.5% ± 7.5% for acute and 71.2% ± 9.0% for nonacute patients (log-rank test, P = .71).
Conclusions:
Endovascular repair of complicated type B aortic dissection with a composite device design demonstrated low all-cause mortality at 30 days, as well as low dissection-related mortality throughout follow-up. Overall, the acute and nonacute cohorts appeared to respond similarly to treatment involving use of the stent-graft and bare metal stent, demonstrating similar clinical outcomes and favorable improvement in aortic remodeling in the thoracic and abdominal aortas.
Related Concept Videos
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Aortic Regurgitation I: Introduction
Study Designs in Epidemiology
Observational studies are those where the researcher does not intervene but rather observes natural variations. They include cross-sectional, cohort, and...
Study Design in Statistics
Does aspirin reduce the risk of heart attacks? Is one brand of fertilizer more effective at growing roses than another? Is fatigue as dangerous to a driver as the influence of alcohol? Questions like these are answered using randomized experiments with proper...
Types of RNA
Three main types of RNA are involved in protein synthesis: messenger RNA (mRNA), transfer RNA (tRNA), and ribosomal RNA (rRNA). These RNAs perform diverse functions and can be broadly classified as protein-coding or non-coding RNA. Non-coding RNAs play important roles in the regulation of gene expression in response to developmental and environmental changes. Non-coding RNAs in prokaryotes can be manipulated to develop more effective antibacterial drugs for human or animal use.
RNA...
Types of Hormones

