Annular versus supra-annular sizing for TAVI in bicuspid aortic valve stenosis
Won-Keun Kim1, Mathias Renker, Andreas Rolf
1Department of Cardiology, Kerckhoff Heart Center, Bad Nauheim, and DZHK (German Center for Cardiovascular Research), partner site Rhein-Main, Frankfurt am Main, Germany.
Aims:
We sought to compare annular versus supra-annular sizing for transcatheter aortic valve implantation (TAVI) in patients with a bicuspid aortic valve (BAV).
Methods And Results:
In this retrospective single-centre analysis, we measured the aortic annulus (Ann) and intercommissural distance (ICD) on multidetector computed tomography scans in 217 BAV patients. With annular sizing being the default method for prosthesis size selection in all cases, we determined clinically relevant sizing errors and assessed the hypothetical impact of supra-annular sizing. Overall there was no significant difference between ICD and Ann (25.1 [23.5; 27.3] vs. 25.4 [23.6; 27.1] mm; p=0.24); intra-individually, ICD was similar to Ann in 26.7%, smaller in 40.1%, and larger in 33.2%. Annular sizing was appropriate in 96.3%, oversized in 0.5%, and undersized in 3.2% of cases. Supra-annular sizing would have resulted in a divergent size selection in 38.7% (smaller: 17.5%, larger: 19.8%, ICD out of range for TAVI prostheses: 1.4%) with potential improvement in a few cases with annular sizing errors, but potential worsening due to improper size selection in a much larger proportion of patients.
Conclusions:
Annular sizing for TAVI in BAV is feasible and safe. The added value of supra-annular sizing is questionable.
More Related Videos
06:51Author Spotlight: Development of a Minimally Invasive Large-Animal Model for Reliable and Reproducible Cardiovascular Research
Published on: October 20, 2023
14:14Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Stenosis I: Introduction
Anatomy of the Heart
Cell Size
Surface Area
Cells can take in nutrients and water via diffusion through the plasma membrane itself or through specific channels in the membrane. The area of the membrane surrounding...
Mitral Stenosis III: Medical Management
Mitral Valve Prolapse I: Introduction