Multi-step Variable Height Photolithography for Valved Multilayer Microfluidic Devices
Published on: January 27, 2017
A portable oligonucleotide-based microfluidic device for the detection of VEGF165 in a three-step suspended-droplet
Chung-Nga Ko1, Han Sun, Ke-Jia Wu
1Department of Chemistry, Hong Kong Baptist University, Kowloon Tong, Hong Kong, China. edmondma@hkbu.edu.hk kangningren@hkbu.edu.hk.
Abstract:
Vascular endothelial growth factor (VEGF165), an important glycosylated protein from the VEGF family, is a type of signal protein highly associated with the development and progression of cancers. In this work, we designed a G-quadruplex-based aptasensing platform for the sensitive and selective detection of VEGF165 in aqueous solution and red blood cell solution. A long-lived phosphorescence iridium(iii) complex (1) with promising photophysical properties and a large Stokes shift was chosen as a selective G-quadruplex probe. The platform could achieve a limit of detection (LOD) down to the picomolar level using a conventional fluorometer. Furthermore, we successfully applied the platform to a three-step suspended droplet (SD)-based microfluidic device for the monitoring of VEGF165. In contrast to the channel-based and digital microfluidic chips, SD-based chips allow easy introduction of liquid samples, valve-free manipulation of multiple reaction steps and flexible volume range. Importantly, polypropylene (PP), a hydrophobic and thermally stable material, was chosen as a substrate to fabricate the chip for the SD-based microfluidic device. The PP-based chip allows the combination of superhydrophobic force, gravity and surface tension for effective driving of the suspended droplet throughout the channel without reverse migration. After assembling all the major components, including a UV lamp, a rotatable chip holder, a filter and a camera into the portable device, we successfully demonstrated the applicability of the device to detect VEGF165 in aqueous solution with a LOD of 0.33 nM at a signal-to-noise ratio (S/N) of 3 and a linear range of 1-100 nM.
Related Concept Videos
What is a Mode?
There can be more than one mode in a data set if multiple values have the same highest frequency. For instance, suppose that the Statistics exam scores of 20 students are: 50; 53; 59; 59; 63; 63; 72; 72; 72; 72; 72; 76; 78; 81; 83; 84; 84; 84; 90; 93. Here, the mode is 72, as it occurs most frequently, five times.
A data set with two modes is called bimodal. For example,...
Transmission-based Precautions I: Contact, Enteric, and Droplets
Contact Precautions:
Contact precautions are the measures taken to prevent the transmission of infectious agents, especially epidemiologically important microorganisms such as MRSA or influenza, primarily transmitted through direct or indirect contact with an...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Rate-Determining Steps
In a multistep reaction mechanism, one of the elementary steps progresses significantly slower than the others. This slowest step is called the rate-limiting step (or rate-determining step). A reaction cannot proceed faster than its slowest step, and hence, the rate-determining step limits the overall reaction rate.
The concept of rate-determining step can be understood from the analogy of a 4-lane freeway with a short-stretch of traffic-bottleneck caused due to...
MOSFET: Enhancement Mode
In their basic form, enhancement-mode MOSFETs are typically non-conductive when the gate-source voltage (Vgs) is zero. This default 'off' state means no...
Modes of Standing Waves: II
For a tube open at one end and closed at the other filled with air, the modes are such that there is always an antinode at the open end and a node at the closed end....