Related Experiment Video
Updated: Jan 24, 2026

Focused Ion Beam Fabrication of LiPON-based Solid-state Lithium-ion Nanobatteries for In Situ Testing
Published on: March 7, 2018
Technical Note: Effect of magnetic fields on the microdosimetry of carbon-ion beams
Tianyuan Dai1,2,3,4, Qiang Li1,2,3,4, Xinguo Liu1,2,3,4
1Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, 73000, China.
Purpose:
To investigate the influence of magnetic fields on the microdosimetry of carbon-ion beams and the scaling effect of tissue equivalent proportional counter (TEPC) defined as the change of energy deposition in a TEPC from that in a microscopic scale region of interest due to the presence of a magnetic field in combination with the TEPC larger physical dimensions.
Methods:
Geant4-based Monte Carlo simulations were conducted to calculate the microdosimetric quantities for carbon-ion beams with different initial energies (10-290 MeV/u) under magnetic fields of various strengths (0.5-3 T). The calculations were performed for a 1 μm spherical volume made of tissue, and for spherical TEPCs of 1 and 10 mm in diameter. Then, values of dose-averaged lineal energy (yD ) were acquired for the different scenarios to analyze the effect of magnetic fields on the microdosimetry of carbon-ion beams and the scaling effect of TEPC.
Results:
The yD values and lineal energy spectra in the 1 μm spherical tissue volume for the scenarios without magnetic field and with magnetic fields of different strengths and directions remained nearly the same for the various energy carbon-ion beams. However, compared with those of the 1 μm spherical tissue volume, an increase of of yD values and an obvious shift of the lineal energy spectra for the TEPCs of 1 and 10 mm in diameter under magnetic fields were found.
Conclusions:
The application of magnetic fields under 3 T has no significant influence on the microdosimetric results of carbon-ion beams. However, there is definitely a scaling effect when using TEPC for microdosimetric study, which alters the reading of TEPC in the presence of magnetic fields. Novel methods to correct the reading of TEPC or scaling effect-resistant microdosimetric measurement detectors are urgently needed to perform experimental microdosimetric studies under magnetic fields.
Related Concept Videos
Magnetic Fields
A magnetic field is defined by the force that a charged particle experiences...
Magnetic Field of a Solenoid
Consider a solenoid with 100 turns wrapped around a cylinder of...
Magnetic Field Lines
Magnetic field lines follow several hard-and-fast rules:
Energy In A Magnetic Field
Take an ideal inductor with zero resistance. Although it's practically impossible, assume that the coil's resistance is so small that it is practically negligible. The loss of the field's energy to dissipate thermal energy (or heat) is thus...
Magnetic Field Of A Current Loop
Magnetic Field due to Moving Charges
Consider a point charge moving with a constant velocity. Like the electric field, the magnetic field at any point is directly proportional to the magnitude of the charge and inversely proportional to the square of the distance between the source point and the field point. However, unlike the electric field, the magnetic field is always perpendicular to the plane containing the line...

