A Novel Approach for Automated Eyelid Measurements in Blepharoptosis Using Digital Image Analysis
Lixia Lou1, Longzhao Yang2, Xin Ye1
1Department of Ophthalmology, College of Medicine, The Second Affiliated Hospital of Zhejiang University , Hangzhou , China.
Abstract:
Purpose: To propose a novel approach for automated measurements of margin reflex distance (MRD) using digital image analysis and to evaluate the agreement between automated and manual measurements of MRD. Materials and Methods: This observational study included 132 eyes of 66 volunteers referred to an oculoplastic clinic for blepharoptosis. Preoperative facial photographs of participants were taken. MRD1 and MRD2 were measured manually by a senior surgeon and automatically by our image-based algorithm. Correlation analyses and Bland-Altman analyses were performed to evaluate the agreement between the two measurements. Results: A strong positive correlation was observed between automated and manual MRD1 measurements, with Spearman's r = 0.968 (95% confidence interval [CI] = 0.949-0.976; P < .001) and intraclass correlation coefficient (ICC) = 0.966 (95% CI = 0.953-0.976; P < .001). The bias between automated and manual MRD1 measurements was 0.02 mm (95% CI = -0.06-0.10 mm), with 95% limits of agreement (LoA) = -0.88 to 0.92 mm. Agreement also existed in MRD2 measurements, with Spearman's r = 0.803 (95% CI = 0.716-0.865; P < .001), ICC = 0.833 (95% CI = 0.772-0.879; P < .001), and bias = 0.34 mm (95% CI = 0.26-0.42 mm), 95% LoA = -0.54 to 1.22 mm. Conclusions: Automated eyelid measurements in blepharoptosis using the image-based approach compare favorably with clinical manual measurements. This novel approach allows an objective assessment of ptosis with high accuracy.
Related Concept Videos
Model-Independent Approaches for Pharmacokinetic Data: Noncompartmental Analysis
One important characteristic of noncompartmental analyses is that drug exposure increases proportionally with increasing doses. This...
Frustration and Conflict: Approach-Approach, Approach-Avoidance
One common type of conflict is the Approach–Approach Conflict. In this case, a person faces two desirable...
Analysis Methods of Pharmacokinetic Data: Model and Model-Independent Approaches
The model approach uses mathematical models to describe changes in drug concentration over time. Pharmacokinetic models help characterize drug behavior in patients, predict drug concentration in the body fluids, calculate optimum dosage regimens, and evaluate the risk of toxicity. However, ensuring that the model fits the experimental data accurately...
Uncertainty in Measurement: Significant Figures
Uncertainty in Measurement: Reading Instruments
Distribution Reliability and Automation