Laboratory study of stationary accretion shock relevant to astrophysical systems

P Mabey1, B Albertazzi2, E Falize3,4

  • 1LULI - CNRS, Ecole Polytechnique, CEA, Université Paris-Saclay, F-91128, Palaiseau Cedex, France. paul.mabey@polytechnique.edu.

Scientific Reports
|June 1, 2019
PubMed

Related Concept Videos

Serum Laboratory Studies, Stool Test, Breath Test01:30

Serum Laboratory Studies, Stool Test, Breath Test

Gastrointestinal (GI) diagnostic studies are pivotal in confirming, ruling out, diagnosing, or staging various diseases, including cancers. Following diagnosis, allocating time for discussions with the patient and providing informational resources is crucial. Diagnostic assessments of the GI tract often occur in outpatient settings like endoscopy suites or GI labs. Preparation for these tests may include dietary restrictions, fasting, liquid bowel preparations, laxatives, enemas, and the...
807
Shock Waves01:16

Shock Waves

While deriving the Doppler formula for the observed frequency of a sound wave, it is assumed that the speed of sound in the medium is greater than the source's speed through it. When this condition is breached, a shock wave occurs.
When the source's speed approaches the speed of sound, constructive interference between successive wavefronts emitted by the source occurs immediately behind it. Initially, scientists believed that this constructive interference would result in such high...
2.5K
Gas Chromatography: Types of Columns and Stationary Phases01:17

Gas Chromatography: Types of Columns and Stationary Phases

Gas chromatography (GC) relies on stationary phases to separate and analyze components in a sample. There are two main types of stationary phases: liquid and solid. Liquid stationary phases are non-volatile, thermally stable, and chemically inert liquids coated onto the column. Solid stationary phases are particles of adsorbent material, such as silica gel or molecular sieves.
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
2.3K
Second Order systems II01:18

Second Order systems II

In an underdamped second-order system, where the damping ratio ζ is between 0 and 1, a unit-step input results in a transfer function that, when transformed using the inverse Laplace method, reveals the output response. The output exhibits a damped sinusoidal oscillation, and the difference between the input and output is termed the error signal. This error signal also demonstrates damped oscillatory behavior. Eventually, as the system reaches a steady state, the error diminishes to zero.
394
First Order Systems01:21

First Order Systems

First-order systems, such as RC circuits, are foundational in understanding dynamic systems due to their straightforward input-output relationship. Analyzing their responses to different input functions under zero initial conditions reveals significant insights into system behavior.
When a first-order system is subjected to a unit-step input, its response is characterized by its transfer function. By applying the Laplace transform of the unit-step input to the transfer function, expanding the...
411
Second Order systems I01:20

Second Order systems I

A servo system exemplifies a second-order system, featuring a proportional controller and load elements that ensure the output position aligns with the input position. The relationship between these components is described by a second-order differential equation. Applying the Laplace transform under zero initial conditions yields the transfer function, showing how inputs are converted to outputs in the system.
By reinterpreting the system, one can derive the closed-loop transfer function, which...
580