Related Experiment Video
Updated: Jan 24, 2026

Longitudinal Micro-Computed Tomography Image Analysis for User-Defined Region of Interest in Critical-Sized Bone Defects
Published on: June 24, 2025
Detection of alveolar bone defects with three different voxel sizes of cone-beam computed tomography: an in vitro
Ting Dong1, Lingjun Yuan1, Lu Liu1
1Department of Orthodontics, Ninth People's Hospital Affiliated to Shanghai Jiao Tong University, School of Medicine, Shanghai, China.
Abstract:
This study was conducted to assess the accuracy of cone-beam computed tomography (CBCT) of different voxel sizes in the detection of alveolar bone defects, and to select the optimal voxel size for clinical use. 46 in-vitro teeth were placed in bovine ribs in which alveolar bone defects were randomly simulated. In total, 32 alveolar bone defects and 14 teeth without periodontal defects were used. CBCT images were acquired with the use of three different voxel sizes: 0.125-mm, 0.2-mm and 0.4-mm. The scan data were 3D-reconstructed in Mimics software and evaluated by two observers with more than 5 years of experience in CBCT. Receiver operating characteristic (ROC) curves and diagnostic values were obtained. Pairwise comparison of ROC curves was made for evaluation of the diagnostic values of different voxel sizes. Kappa statistics assessed the observer reliability. Results were considered significant at P < 0.05. It showed no statistically significant difference between 0.125-mm group and 0.2-mm group, but 0.4-mm group had lower Az values that differed significantly from 0.125-mm and 0.2-mm groups (P < 0.05). Based on diagnostic value and radiation protection, 0.2-mm voxel size may be a good choice for the detection of bone defects with CBCT.
More Related Videos
05:37Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Alveoli and Alveolar Ducts
Deflection of a Beam
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...
Lumber Defects
Shakes are minor fractures that run along or across the wood's annual rings, while wane is...