Related Experiment Video
Updated: Jan 24, 2026

Preventing the Spread of Malaria and Dengue Fever Using Genetically Modified Mosquitoes
Published on: July 4, 2007
Biopesticides improve efficiency of the sterile insect technique for controlling mosquito-driven dengue epidemics
David R J Pleydell1,2, Jérémy Bouyer1,3
11CIRAD, INRA, University of Montpellier, UMR ASTRE, F-34398 Montpellier, France.
Abstract:
Various mosquito control methods use factory raised males to suppress vector densities. But the efficiency of these methods is currently insufficient to prevent epidemics of arbovirus diseases such as dengue, chikungunya or Zika. Suggestions that the sterile insect technique (SIT) could be "boosted" by applying biopesticides to sterile males remain unquantified. Here, we assess mathematically the gains to SIT for Aedes control of either: boosting with the pupicide pyriproxifen (BSIT); or, contaminating mosquitoes at auto-dissemination stations. Thresholds in sterile male release rate and competitiveness are identified, above which mosquitoes are eliminated asymptotically. Boosting reduces these thresholds and aids population destabilisation, even at sub-threshold release rates. No equivalent bifurcation exists in the auto-dissemination sub-model. Analysis suggests that BSIT can reduce by over 95% the total release required to circumvent dengue epidemics compared to SIT. We conclude, BSIT provides a powerful new tool for the integrated management of mosquito borne diseases.
More Related Videos
08:58Preparing Irradiated and Marked Male Aedes aegypti Mosquitoes for Release in an Operational Sterile Insect Technique Program
Published on: March 12, 2021
15:03Building a Better Mosquito: Identifying the Genes Enabling Malaria and Dengue Fever Resistance in A. gambiae and A. aegypti Mosquitoes
Published on: July 4, 2007
Related Concept Videos
Osmoregulation in Insects
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
ATP Driven Pumps I: An Overview
There are four main types of ATP-driven pumps - P-type, V-type, F-type, and ABC transporter. All these pumps are of varying complexities and...
Combinatorial Gene Control
The expression of more than 30,000 genes is controlled by approximately 2000-3000 transcription factors. This is possible because a single transcription factor can recognize more than one regulatory sequence. The specificity in gene...