A Comparison of Four Presumptive Tests for the Detection of Blood on Dark Materials
Julie Butler1, Janet Chaseling2, Kirsty Wright3
1Brisbane Scientific Section, Queensland Police Service, 200 Roma Street, Brisbane, Queensland, 4000, Australia.
Detection of blood on dark materials is difficult for crime scene examiners so presumptive tests are used to assist. This study compared the ability of luminol, leuko crystal violet, tetramethylbenzidine, and Combur Test®E to detect whole, diluted blood (1:100) and a key-shaped blood transfer stain (1:10), on dark cotton sheeting, tea towel, socks, synthetic carpet, and car mats. Powdered bleach was used to evaluate specificity of the blood detection tests. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and overall misclassification rate (OMR) assessed the quality of the blood tests. Luminol was the preferred test for diluted blood having the highest sensitivity (79%-96%), NPV (66%-93%), and the lowest OMR (3%-15%). Luminol was also found to be most efficient with a testing time on 25 items of 2 h 50 min compared with up to 8 h. Overall, luminol was the most effective method, also providing information on bloodstain patterns.
Detection of blood on dark materials is difficult for crime scene examiners so presumptive tests are used to assist. This study compared the ability of luminol, leuko crystal violet, tetramethylbenzidine, and Combur Test®E to detect whole, diluted blood (1:100) and a key-shaped blood transfer stain (1:10), on dark cotton sheeting, tea towel, socks, synthetic carpet, and car mats. Powdered bleach was used to evaluate specificity of the blood detection tests. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and overall misclassification rate (OMR) assessed the quality of the blood tests. Luminol was the preferred test for diluted blood having the highest sensitivity (79%-96%), NPV (66%-93%), and the lowest OMR (3%-15%). Luminol was also found to be most efficient with a testing time on 25 items of 2 h 50 min compared with up to 8 h. Overall, luminol was the most effective method, also providing information on bloodstain patterns.
More Related Videos
Related Concept Videos
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Dark Triad and Person Perception
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Evolutionary Relationships through Genome Comparisons
Members Made of Elastoplastic Material
As the bending moment...
Genetic Material