Related Experiment Video
Updated: Jan 24, 2026

Reverse Transcription Loop-Mediated Isothermal Amplification RT-LAMP Assay for the Specific and Rapid Detection of Tilapia Lake Virus
Published on: May 18, 2020
Development and evaluation of a loop-mediated isothermal amplification assay for rapid detection of Leishmania
Jordanna Luiza de Lima Celeste1, Roberta Lima Caldeira2, Simone da Fonseca Pires1
1Departamento de Parasitologia, ICB, Universidade Federal de Minas Gerais, CP: 486 - CEP: 31.270-901, Belo Horizonte, Minas Gerais, Brazil.
Abstract:
In Brazil, Leishmania amazonensis is one of the etiological agents of tegumentary leishmaniasis and can cause a wide spectrum of diseases in humans, resulting in cutaneous, mucosal, diffuse, and even visceral leishmaniasis. Besides, this species has also been reported to affect dogs, causing typical symptoms of visceral disease. Unfortunately, the diagnostic of the Leishmania species is not routinely performed due to the difficulties of the available methods. In view of this, different molecular methods have been used in an attempt to solve the problem of diagnosis. Loop-mediated isothermal amplification (LAMP) is a relatively new nucleic acid amplification method, which has been successfully applied in the diagnosis of Leishmania spp. infections. However, this is the first work that standardizes a specific LAMP reaction for L. amazonensis. The set of primers selected were designed from the kDNA minicircle sequence of the L. amazonensis (GenBank: U19810.1). The LAMP assay developed in the present study showed 100% specificity and 89% sensitivity when compared with conventional PCR and was more sensitive than qPCR. In addition, the LAMP reaction developed here was able to amplify a qPCR sample with a parasite load of only 28 parasites in 50 ng of DNA. Consequently, considering the LAMP reaction specific to L. amazonensis and several advantages of the method (such as high efficiency, sensitivity and specificity), we believe that this reaction can be used as a promising diagnostic tool in clinical practice, field studies, and research.
Related Concept Videos
RACE - Rapid Amplification of cDNA Ends
Isothermal Processes
An ideal gas can also undergo isothermal expansion or compression.
For example, consider 1 mole of an ideal gas inside an isolated cylinder at initial volume V...
Receptor-mediated Endocytosis
Feedback Loops
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
Positive and Negative Feedback Loops

